88625Q
1.INSPECT ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Room Temperature Sensor (Cooler Thermistor)) |
*b | Sensing Portion |
| *c | Resistance (kΩ) | *d | Allowable Range |
| *e | Temperature (°C (°F)) | - | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I57-1 (+) - I57-2 (-) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| I57-1 (+) - I57-2 (-) | 15°C (59°F) | 2.45 to 2.88 kΩ |
| I57-1 (+) - I57-2 (-) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| I57-1 (+) - I57-2 (-) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| I57-1 (+) - I57-2 (-) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| I57-1 (+) - I57-2 (-) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| I57-1 (+) - I57-2 (-) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| I57-1 (+) - I57-2 (-) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| I57-1 (+) - I57-2 (-) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| I57-1 (+) - I57-2 (-) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| I57-1 (+) - I57-2 (-) | 60°C (140°F) | 0.36 to 0.50 kΩ |
If the resistance is not as specified, replace the room temperature sensor (cooler thermistor).
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).