Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)
RM19V0EQ _58 Vehicle Interior _014613 HEATING / AIR CONDITIONING _0074198 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  TERMINALS OF ECU  


AIR CONDITIONING AMPLIFIER ASSEMBLY


E226604
5.258,0.153 5.439,0.337 0.182,0.184 10 z1 3.105,0.159 3.414,0.315 0.309,0.156 10 I77 3.03,0.112 3.366,0.336 0.336,0.224 5.162,0.112 5.498,0.336 0.336,0.224

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
I77-1 (IG+) - I77-14 (GND) B - W-B Power source (IG) Ignition switch ON 11 to 14 V
I77-1 (IG+) - I77-14 (GND) B - W-B Power source (IG) Ignition switch off Below 1 V
I77-2 (SOL+) - I77-14 (GND) W - W-B*1
GR - W-B*2
Compressor solenoid operation signal Engine running
A/C switch: on
Blower switch: LO
Pulse generation
(See waveform 1)
I77-5 (TAM) - I77-13 (SG-2) P - GR Ambient temperature sensor signal Ignition switch ON
Ambient temperature: 25°C (77°F)
1.35 to 1.75 V
I77-5 (TAM) - I77-13 (SG-2) P - GR Ambient temperature sensor signal Ignition switch ON
Ambient temperature: 40°C (104°F)
0.9 to 1.2 V
I77-7 (FLOQ) - I77-13 (SG-2) G - GR*1
LG - GR*2
A/C flow sensor signal Ignition switch ON
A/C switch: off
3.8 to 4.2 V
I77-7 (FLOQ) - I77-13 (SG-2) G - GR*1
LG - GR*2
A/C flow sensor signal Ignition switch ON
A/C switch: on
Blower switch: HI
0.7 to 3.8 V
I77-9 (PRE) - I77-13 (SG-2) R - GR Air conditioning pressure sensor signal Engine running
A/C system operating
Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.9 kgf/cm2, 439 psi))
4.80 V or higher
I77-9 (PRE) - I77-13 (SG-2) R - GR Air conditioning pressure sensor signal Engine running
A/C system operating
Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 25 psi))
Below 0.50 V
I77-9 (PRE) - I77-13 (SG-2) R - GR Air conditioning pressure sensor signal Engine running
A/C system operating
Refrigerant pressure: Normal pressure (less than 3025 kPa (30.9 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
0.50 to 4.80 V
I77-10 (S5-3) - I77-13 (SG-2) V - GR Power supply for air conditioning pressure sensor Ignition switch ON
A/C switch: on
4.75 to 5.25 V
I77-10 (S5-3) - I77-13 (SG-2) V - GR Power supply for air conditioning pressure sensor Ignition switch ON
A/C switch: off
Below 1 V
I77-11 (CANH) - I77-12 (CANL) V - W CAN communication system CAN communication circuit Pulse generation
I77-13 (SG-2) - Body ground GR - Body ground Ground for air conditioning pressure sensor, ambient temperature sensor Always Below 1 V
I77-14 (GND) - Body ground W-B - Body ground Ground for main power supply Always Below 1 V
I77-21 (B) - I77-14 (GND) Y - W-B Power source (Back-up) Always 11 to 14 V
I77-22 (BLW) - I77-14 (GND) R - W-B Blower motor speed control signal Ignition switch ON
Blower switch: LO
Pulse generation
(See waveform 2)
I77-30 (S5-1) - I77-13 (SG-2) B - GR Power supply for A/C flow sensor Ignition switch off Below 1 V
I77-30 (S5-1) - I77-13 (SG-2) B - GR Power supply for A/C flow sensor Ignition switch ON 4.5 to 5.5 V
I77-37 (LIN1) - I77-14 (GND) V - W-B LIN communication signal Ignition switch ON Pulse generation
z1-2 (BUS G) - Body ground - Ground for BUS IC Always Below 1 V
z1-3 (BUS) - z1-2 (BUS G) - BUS IC control signal Ignition switch ON Pulse generation
z1-4 (B BUS) - z1-2 (BUS G) - Power supply for BUS IC Always 11 to 14 V
z1-5 (SGA) - Body ground - Ground for evaporator temperature sensor Always Below 1 V
z1-6 (TEA) - z1-5 (SGA) - Evaporator temperature sensor signal Ignition switch ON
Evaporator temperature: 0°C (32°F)
1.7 to 2.1 V
z1-6 (TEA) - z1-5 (SGA) - Evaporator temperature sensor signal Ignition switch ON
Evaporator temperature: 15°C (59°F)
0.9 to 1.3 V

*1: for LHD

*2: for RHD


a.
E106664
2.99,1.188 3.396,1.427 0.406,0.24 10 false GND

Waveform 1:

Item Content
Terminal No. I77-2 (SOL+) - I77-14 (GND)
Tool Setting 5 V/DIV., 500 μs/DIV.
Vehicle Condition Engine running
A/C switch: on
Blower switch: LO


b.
E103396
2.917,1.656 3.313,1.865 0.396,0.208 10 false GND

Waveform 2:

Item Content
Terminal No. I77-22 (BLW) - I77-14 (GND)
Tool Setting 1 V/DIV., 500 μs/DIV.
Vehicle Condition Ignition switch ON
Blower switch: LO



AIR CONDITIONING CONTROL ASSEMBLY


E182384
3.604,0.261 3.872,0.479 0.267,0.218 10 I56 3.539,0.22 3.861,0.439 0.322,0.219

HINT:

Check from the rear of the connector while it is connected to the air conditioning control assembly.


Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
I56-2 (IG+) - I56-6 (GND) R - W-B Power source (IG) Ignition switch off Below 1 V
I56-2 (IG+) - I56-6 (GND) R - W-B Power source (IG) Ignition switch ON 11 to 14 V
I56-6 (GND) - Body ground W-B - Body ground Ground for air conditioning control assembly Always Below 1 V
I56-9 (LIN1) - Body ground V - Body ground LIN communication signal Ignition switch ON Pulse generation
I56-11 (ILL+) - I56-15 (ILL-) G - W-B Light control switch signal Light control switch off Below 1 V
I56-11 (ILL+) - I56-15 (ILL-) G - W-B Light control switch signal Light control switch on 11 to 14 V
I56-15 (ILL-) - Body ground W-B - Body ground Ground for air conditioning control assembly illumination Always Below 1 V