HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temp Sensor Ambient temperature sensor (Thermistor assembly) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
- -
Evaporator Fin Thermistor Evaporator temperature sensor (No. 1 cooler thermistor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed -
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed -
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed -
Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
Regulator Pressure Sensor Air conditioning pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual pressure is displayed -
Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse Min.: 0
Max.: 255
for LHD:
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
for RHD:
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
-
Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse Min.: 0
Max.: 255
for LHD:
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
for RHD:
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
-
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse Min.: 0
Max.: 255
FACE: 8 (pulse)
B/L: 30 (pulse)
FOOT (except MAX. HOT): 67 (pulse)
FOOT (MAX. HOT): 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
-
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse Min.: 0
Max.: 255
FACE: 8 (pulse)
B/L: 30 (pulse)
FOOT (except MAX. HOT): 67 (pulse)
FOOT (MAX. HOT): 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
-
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) target pulse Min.: 0
Max.: 255
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
-
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly (air inlet) actual pulse Min.: 0
Max.: 255
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
-
Evaporator Control Evaporator Control Auto or Manual Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Flow Sensor Flow sensor Min.: 0 V
Max.: 5 V
Ignition switch ON: 0.3 to 4.7 V Flow sensor is malfunctioning when a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds.
A/C Cutoff Signal A/C control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -


ACTIVE TEST


Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0, Max.: 31 -
Magnetic Clutch Relay A/C system operation OFF, ON -
Defogger Relay (Rear) Defogger relay (engine room junction block assembly) OFF, ON -
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse Min.: 0, Max.: 255 for LHD:
Operates between 7 and 105 pulses
for RHD:
Operates between 5 and 103 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse Min.: 0, Max.: 255 Operates between 8 and 97 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) motor target pulse Min.: 0, Max.: 255 Operates between 7 and 28 pulses