Home › Drivetrain › U760E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM
RM19V0EQ _52 Drivetrain _014582 U760E AUTOMATIC TRANSMISSION / TRANSAXLE _0076198 AUTOMATIC TRANSAXLE SYSTEM C

U760E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0798  Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3)  


DESCRIPTION

Changing from 1st to 6th is performed by the ECM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated (See page Drivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0798 Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3) The ECM checks for an open or short in the shift solenoid valve SL3 circuit while driving and shifting gears. (1-trip detection logic)
·

Output signal duty equals to 100%.

(NOTE: SL3 output signal duty is less than 100% under normal condition.)


·

Open or short in shift solenoid valve SL3 circuit

·

Shift solenoid valve SL3

·

Wiring harness connector

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves on or off (In case of an open or short circuit, the ECM stops sending current to the circuit.)

(See page Drivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART).

WIRING DIAGRAM

C239277E27
5.677,4.229 6.104,4.417 0.427,0.188 10 false ECM 5.083,1.479 5.51,1.667 0.427,0.188 10 false SL3+ 5.083,2.844 5.51,3.031 0.427,0.188 10 false SL3- 3.625,1.531 4.052,1.719 0.427,0.188 10 false SL3+ 3.625,2.875 4.052,3.063 0.427,0.188 10 false SL3- 1.625,1.948 2.604,2.281 0.979,0.333 10 false Shift Solenoid Valve SL3 1.021,3.417 2.583,3.604 1.563,0.188 10 false Automatic Transaxle 3.031,3.417 4.031,3.771 1,0.354 10 false Wiring Harness Connector 3.115,1.531 3.542,1.719 0.427,0.188 10 false SL3+ 3.115,2.865 3.542,3.052 0.427,0.188 10 false SL3- 2.313,1.531 2.74,1.719 0.427,0.188 10 false SL3+ 2.313,2.875 2.74,3.063 0.427,0.188 10 false SL3- 5.198,4.229 5.552,4.385 0.354,0.156 10 false E26 4.813,1.479 5.083,1.635 0.271,0.156 10 false 11 4.813,2.865 5.083,3.021 0.271,0.156 10 false 10 2.802,2.563 3.094,2.719 0.292,0.156 10 false 15 4.083,1.167 4.375,1.333 0.292,0.167 10 false 19 4.083,2.563 4.365,2.729 0.281,0.167 10 false 18 4.073,2.76 4.354,2.917 0.281,0.156 10 false E8 4.073,1.365 4.354,1.521 0.281,0.156 10 false E8 2.844,2.76 3.177,2.917 0.333,0.156 10 false A 2.844,1.375 3.198,1.531 0.354,0.156 10 false A 2.802,1.177 3.083,1.333 0.281,0.156 10 false 16

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL3 CIRCUIT)
a.
C240434C04
0.24,0.958 0.698,1.177 0.458,0.219 0.979,2.438 1.073,1.729 false 1.135,1.729 1.688,2.385 false 0.271,0.188 0.615,0.385 0.344,0.198 10 *a 0.354,0.99 0.75,1.167 0.396,0.177 10 E26 1.625,2.438 2.052,2.625 0.427,0.188 10 SL3+ 0.771,2.458 1.198,2.646 0.427,0.188 10 SL3-
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E26-11 (SL3+) - E26-10 (SL3-) 20°C (68°F) 5.0 to 5.6 Ω
E26-11 (SL3+) - Body ground and other terminals Always 10 kΩ or higher
E26-10 (SL3-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
a.

Disconnect the harness connector from the wiring harness connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E26-11 (SL3+) - E8-19 (SL3+) Always Below 1 Ω
E26-10 (SL3-) - E8-18 (SL3-) Always Below 1 Ω
E26-11 (SL3+) or E8-19 (SL3+) - Body ground and other terminals Always 10 kΩ or higher
E26-10 (SL3-) or E8-18 (SL3-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT TRANSMISSION WIRE (SL3)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT TRANSMISSION WIRE (SL3)
a.
C133212C05
2.333,0.76 2.646,0.99 0.313,0.229 1.417,0.979 2.208,1.365 false 1.521,0.865 2.281,0.573 false 2.25,1.292 2.646,1.521 0.396,0.229 10 SL3+ 2.344,0.448 2.76,0.646 0.417,0.198 10 SL3- 2.438,0.792 2.625,0.969 0.188,0.177 10 A 0.667,0.323 0.896,0.552 0.229,0.229 10 *a
*a Component without harness connected
(Transmission Wire)


Remove the wiring harness connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-16 (SL3+) - A-15 (SL3-) 20°C (68°F) 5.0 to 5.6 Ω
A-16 (SL3+) - Body ground and other terminals Always 10 kΩ or higher
A-15 (SL3-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

4.INSPECT SHIFT SOLENOID VALVE SL3
4.INSPECT SHIFT SOLENOID VALVE SL3
a.
C201747C02
1.49,0.875 0.635,0.646 false 1.781,0.865 2.479,0.625 false 1.49,3.125 0.635,2.896 false 1.781,3.125 2.479,2.885 false 0.49,0.521 0.667,0.719 0.177,0.198 10 1 2.531,0.5 2.708,0.698 0.177,0.198 10 2 1.177,4.198 1.385,4.406 0.208,0.208 10 (-) 1.917,4.208 2.146,4.406 0.229,0.198 10 (+) 0.51,2.771 0.688,2.969 0.177,0.198 10 1 2.521,2.76 2.698,2.958 0.177,0.198 10 2 0.135,0.135 0.354,0.344 0.219,0.208 10 *1
*1 Shift Solenoid Valve SL3


Remove shift solenoid valve SL3.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

OK:

Valve moves and makes an operating sound.



Result:
Proceed to
OK
NG



OK

NG