Home › Drivetrain › U760E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM
RM19V0EQ _52 Drivetrain _014582 U760E AUTOMATIC TRANSMISSION / TRANSAXLE _0076198 AUTOMATIC TRANSAXLE SYSTEM C

U760E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2769  Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  P2770  Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  


DESCRIPTION

Shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) ECM detects a short in the shift solenoid valve SL circuit when the shift solenoid valve SL is operated (2 trip detection logic).
·

Short in shift solenoid valve SL circuit

·

Shift solenoid valve SL

·

Wiring Harness Connector

·

ECM


Comes on DTC stored
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) ECM detects an open in the shift solenoid valve SL circuit when the shift solenoid valve SL is not operated (2 trip detection logic).
·

Open in shift solenoid valve SL circuit

·

Shift solenoid valve SL

·

Wiring Harness Connector

·

ECM


Comes on DTC stored

Fail-safe function:

If the ECM detects a malfunction, it turns shift solenoid valve SL off.

MONITOR DESCRIPTION

Based on the signals from the throttle position sensor, the air flow meter and the crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smoother torque converter engagement. Shift solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short circuit for shift solenoid valve SL, it will illuminate the MIL.

WIRING DIAGRAM

C239278E02
5.677,4.271 6.104,4.448 0.427,0.177 10 ECM 5.104,1.302 5.344,1.469 0.24,0.167 10 SL 3.698,1.188 3.938,1.354 0.24,0.167 10 SL 1.646,2.052 2.531,2.438 0.885,0.385 10 Shift Solenoid Valve SL 1.115,3.5 2.427,3.677 1.313,0.177 10 Automatic Transaxle 3.021,3.5 4.01,3.833 0.99,0.333 10 Wiring Harness Connector 5.677,4.115 5.969,4.271 0.292,0.156 10 E26 4.083,1.083 4.229,1.26 0.146,0.177 10 6 2.781,1.083 2.896,1.26 0.115,0.177 10 6 3.063,1.188 3.302,1.354 0.24,0.167 10 SL 2.427,1.188 2.667,1.354 0.24,0.167 10 SL 4.896,1.198 5.042,1.375 0.146,0.177 10 3 2.76,1.292 3.052,1.448 0.292,0.156 10 A 4.021,1.292 4.313,1.448 0.292,0.156 10 E8

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL CIRCUIT)
a.
C233488C35
1.469,0.313 1.958,0.604 0.49,0.292 0.542,1.052 0.76,1.75 0.76,1.75 0.927,1.75 false 0.083,0.042 0.323,0.24 0.24,0.198 10 false *a 0.99,1.677 1.385,1.844 0.396,0.167 10 false SL 1.594,0.375 1.896,0.552 0.302,0.177 10 false E26
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E26-3 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
a.

Disconnect the harness connector from the wiring harness connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E26-3 (SL) - E8-6 (SL) Always Below 1 Ω
E26-3 (SL) - Body ground and other terminals Always 10 kΩ or higher
E8-6 (SL) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
a.
C133212C21
2.302,0.667 2.667,0.969 0.365,0.302 1.927,0.729 2.344,0.406 false 2.417,0.292 2.792,0.531 0.375,0.24 10 SL 0.656,0.302 0.969,0.563 0.313,0.26 10 *a 2.438,0.729 2.625,0.906 0.188,0.177 10 A
*a Component without harness connected
(Transmission Wire)


Remove the wiring harness connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-6 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

4.INSPECT SHIFT SOLENOID VALVE SL
4.INSPECT SHIFT SOLENOID VALVE SL
a.
C133217C02
0.203,0.177 0.424,0.335 0.221,0.158 10 *1
*1 Shift Solenoid Valve SL


Remove shift solenoid valve SL.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (SL) - Solenoid Body (SL) 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG