Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM › 2011.10–2015.04
RM19V0EQ _58 Vehicle Interior _014608 METER / GAUGE / DISPLAY _0074143 METER / GAUGE SYSTEM J

METER / GAUGE / DISPLAY  METER / GAUGE SYSTEM  Entire Combination Meter does not Operate  


DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

E143732E40
5.26,5.052 7.135,5.219 1.875,0.167 10 Combination Meter Assembly 6.146,1.292 6.427,1.448 0.281,0.156 10 B 6.146,2.271 6.531,2.427 0.385,0.156 10 IG+ 6.146,3.271 6.385,3.427 0.24,0.156 10 ES 5.875,1.167 6.052,1.323 0.177,0.156 10 1 5.875,2.156 6.052,2.313 0.177,0.156 10 13 5.26,4.917 5.542,5.073 0.281,0.156 10 I18 5.875,3.156 6.052,3.313 0.177,0.156 10 7 3.323,2.396 4.208,2.688 0.885,0.292 10 METER-IG2 4.479,1.448 5.354,1.594 0.875,0.146 10 ECU-B NO. 1 2.24,1.26 3.583,1.51 1.344,0.25 10 from Battery 0.198,2.271 1.302,2.417 1.104,0.146 10 from IG2 Relay

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses of circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
a.
E224284C15
0.271,1.875 0.729,2.156 0.458,0.281 1.729,1.906 1.729,0.698 1.729,0.698 1.927,0.698 false 0.979,2.146 0.979,2.552 0.979,2.552 0.781,2.552 false 0.979,1.906 0.979,1.25 0.979,1.25 0.781,1.25 false 0.115,0.083 0.396,0.365 0.281,0.281 10 *a 1.969,0.625 2.458,1 0.49,0.375 10 ES 0.656,1.177 1.188,1.417 0.531,0.24 10 B 0.417,1.927 0.917,2.219 0.5,0.292 10 I18 0.542,2.479 1.073,2.719 0.531,0.24 10 IG+
*a Front view of wire harness connector
(to Combination Meter Assembly)


Disconnect the I18 combination meter assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I18-7 (ES) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I18-13 (IG+) - Body ground Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
I18-1 (B) - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR