Home › Steering › POWER ASSIST SYSTEMS › POWER STEERING SYSTEM › 2011.10–2015.04
RM19V0EQ _55 Steering _014596 POWER ASSIST SYSTEMS _0074061 POWER STEERING SYSTEM U

POWER ASSIST SYSTEMS  POWER STEERING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Turn the ignition switch off.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the intelligent tester on.


e.

Enter the following menus: Chassis / EMPS / Data List.


f.

According to the display on the intelligent tester, read the Data List.

Chassis > EMPS > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Meter Vehicle Velocity Vehicle speed from meter Min.: 0.0 km/h (0.0 mph)
Max.: 300.0 km/h (186.4 mph)
·

Engine running and vehicle stopped: 0 km/h (0 mph)

·

Engine running and vehicle driven at a constant speed: No significant fluctuation


-
Engine Revolution Engine speed Min.: 0 rpm
Max.: 12800 rpm
Engine running at a constant speed: No significant fluctuation -
Motor Actual Current Amount of current to motor Min.: -327.68 A
Max.: 327.67 A
Engine running and steering wheel being turned: The value rises -
Command Value Current Requested current to motor Min.: -327.68 A
Max.: 327.67 A
Engine running and steering wheel being turned: Value changes in proportion to steering effort
-The value increases when turning left and decreases when turning right
-
Steering Angle Velocity Steering angle speed Min.: -32768 deg/s
Max.: 32767 deg/s
Engine running and steering wheel being turned: Value changes in proportion to steering speed
-The value increases when turning left and decreases when turning right
-
Thermistor Temperature ECU substrate temperature Min.: -40.0°C (-40.0°F)
Max.: 150.0°C (302.0°F)
Engine running: -40°C to 150°C (-40°F to 302°F) -
PIG Power Supply Power source voltage to active motor Min.: 0.0000 V
Max.: 20.1531 V
Engine running and steering wheel being turned: 9 to 16 V -
IG Power Supply IG power source voltage Min.: 0.0000 V
Max.: 20.1531 V
Ignition switch ON: 9 to 16 V -
Steering Wheel Torque Steering wheel torque Min.: -327.68 Nm
Max.: 7.00 Nm
Engine running and steering wheel being turned: Value changes in proportion to steering effort
-The value increases when turning left and decreases when turning right
-
Motor Rotation Angle Motor rotation angle Min.: 0.000 deg
Max.: 1441.770 deg
Engine running and steering wheel being turned: During steering operation, motor rotation angle value changes from 0 to 360° -
Motor Voltage Motor power supply voltage Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: 9 to 16 V -
Motor Terminal Volt(U) Motor terminal voltage (A phase) Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: Value changes within 4 to 35 V range -
Motor Terminal Volt(V) Motor terminal voltage (B phase) Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: Value changes within 4 to 35 V range -
Motor Terminal Volt(W) Motor terminal voltage (C phase) Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: Value changes within 4 to 35 V range -
Torque Sensor 1 Output Torque sensor voltage Min.: 0.0000 V
Max.: 4.9725 V
·

Engine running and steering wheel not being turned (without load): 2.3 to 2.7 V

·

Engine running and steering wheel being turned to the right with vehicle stopped: 2.5 to 4.7 V

·

Engine running and steering wheel being turned to the left with vehicle stopped: 0.3 to 2.5 V


-
Torque Sensor 2 Output Torque sensor voltage Min.: 0.0000 V
Max.: 4.9725 V
·

Engine running and steering wheel not being turned (without load): 2.3 to 2.7 V

·

Engine running and steering wheel being turned to the right with vehicle stopped: 0.3 to 2.5 V

·

Engine running and steering wheel being turned to the left with vehicle stopped: 2.5 to 4.7 V


-
IG ON/OFF Times Number of times of ignition switch ON/OFF after fail detection Min.: 0 times
Max.: 65535 times
- This value indicates the number of times of ignition switch ON/OFF after the latest DTC detection.
Motor Overheat Record Continuous overheat prevention control record Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Motor Lo Power Record PIG power source voltage drop record Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Eng Rev Inter Record Record of engine speed signal interruption Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Spd Sig Invalid Record Record of vehicle speed signal invalid Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Battery Voltage Lo Record Battery voltage reduction history Min.: 0 times
Max.: 65535 times
0 to 65535 -
Battery Voltage Battery voltage Min.: 0.0 V
Max.: 25.5 V
Ignition switch ON: 9 to 16 V -
PS Assist Signal Power steering assist signal ON or OFF
·

Ignition switch ON: OFF

·

Engine running: ON


-
The Number of DTCs Number of detected DTCs when freeze frame data stored Min.: 0
Max.: 255
0 to 255 -