2AR-FE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27415 1.INSPECT GENERATOR PULLEY WITH CLUTCH

a.
A208964C02
0.86,0.861 1.03,1.022 0.17,0.161 10 *a 2.401,0.861 2.571,1.022 0.17,0.161 10 *b
*a Free
*b Lock


Hold the center of the generator pulley with clutch, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

OK:

The outer ring turns counterclockwise and does not turn clockwise.


If the result is not as specified, replace the generator pulley with clutch.


Hide 27310B 2.INSPECT GENERATOR DRIVE END FRAME BEARING

a.
A192785

Check that the generator drive end frame bearing is not rough or worn and that it rotates smoothly.

If the generator drive end frame bearing is rough or worn, or does not rotate smoothly, replace the generator drive end frame bearing.


Hide 27370 3.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A128079C12
0.627,0.709 0.823,0.866 0.197,0.157 10 *a
*a Length


Using a vernier caliper, measure the brush length.

Standard Length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum Length:

4.5 mm (0.177 in.)


If the brush length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 4.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A192784

Check that the generator rotor bearing is not rough or worn and that it rotates smoothly.

If the generator rotor bearing is rough or worn, or does not rotate smoothly, replace the generator rotor assembly.


b.
A298009C04
1.698,0.896 2.406,0.417 2.406,0.417 1.854,0.948 true 2.469,0.333 2.781,0.49 0.313,0.156 10 false *a
*a Slip Ring


Check the generator rotor assembly for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring Approx. 20°C (68°F) 1.8 to 2.2 Ω


If the result is not as specified, replace the generator rotor assembly.



c.
A298010C07
0.333,0.188 0.646,0.188 0.646,0.188 0.948,0.781 true 1.802,1 2.135,0.615 2.135,0.615 2.396,0.615 true 2.448,0.5 2.76,0.656 0.313,0.156 10 false *a 0.167,0.083 0.479,0.24 0.313,0.156 10 false *b
*a Slip Ring
*b Rotor


Check the generator rotor assembly for a short to ground.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor Always 10 MΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.

Check the slip ring.

i.

Check that the slip rings are not rough or scored.

If the slip rings are rough or scored, replace the generator rotor assembly.


ii.
A097470C04
0.646,0.094 0.813,0.25 0.167,0.156 10 *a
*a Diameter


Using a vernier caliper, measure the slip ring diameter.

Standard Diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum Diameter:

14 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.