Home › Steering › POWER ASSIST SYSTEMS › POWER STEERING SYSTEM › from 2015.04
RM19V0EQ _55 Steering _014596 POWER ASSIST SYSTEMS _0074061 POWER STEERING SYSTEM U

POWER ASSIST SYSTEMS  POWER STEERING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Turn the ignition switch off.


b.

Connect the intelligent tester to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the intelligent tester on.


e.

Enter the following menus: Chassis / EMPS / Data List.


f.

According to the display on the intelligent tester, read the Data List.

Chassis > EMPS > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Meter Vehicle Velocity Vehicle speed from meter Min.: 0.0 km/h (0.0 mph)
Max.: 300.0 km/h (186.4 mph)
·

Engine running and vehicle stopped: 0 km/h (0 mph)

·

Engine running and vehicle driven at a constant speed: No significant fluctuation


-
Engine Revolution Engine speed Min.: 0 rpm
Max.: 12800 rpm
Engine running at a constant speed: No significant fluctuation -
Motor Actual Current Amount of current to motor Min.: -327.68 A
Max.: 327.67 A
Engine running and steering wheel being turned: The value rises -
Command Value Current Requested current to motor Min.: -327.68 A
Max.: 327.67 A
Engine running and steering wheel being turned: Value changes in proportion to steering effort
-The value increases when turning left and decreases when turning right
-
Steering Angle Velocity Steering angle speed Min.: -32768 deg/s
Max.: 32767 deg/s
Engine running and steering wheel being turned: Value changes in proportion to steering speed
-The value increases when turning left and decreases when turning right
-
Thermistor Temperature ECU substrate temperature Min.: -40.0°C (-40.0°F)
Max.: 150.0°C (302.0°F)
Engine running: -40°C to 150°C (-40°F to 302°F) -
PIG Power Supply Power source voltage to active motor Min.: 0.0000 V
Max.: 20.1531 V
Engine running and steering wheel being turned: 9 to 16 V -
IG Power Supply IG power source voltage Min.: 0.0000 V
Max.: 20.1531 V
Ignition switch ON: 9 to 16 V -
Steering Wheel Torque Steering wheel torque Min.: -327.68 Nm
Max.: 7.00 Nm
Engine running and steering wheel being turned: Value changes in proportion to steering effort
-The value increases when turning left and decreases when turning right
-
Motor Rotation Angle Motor rotation angle Min.: 0.000 deg
Max.: 1441.770 deg
Engine running and steering wheel being turned: During steering operation, motor rotation angle value changes from 0 to 360° -
Motor Voltage Motor power supply voltage Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: 9 to 16 V -
Motor Terminal Volt(U) Motor terminal voltage (A phase) Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: Value changes within 4 to 35 V range -
Motor Terminal Volt(V) Motor terminal voltage (B phase) Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: Value changes within 4 to 35 V range -
Motor Terminal Volt(W) Motor terminal voltage (C phase) Min.: 0.000 V
Max.: 98.000 V
Engine running and steering wheel being turned: Value changes within 4 to 35 V range -
Torque Sensor 1 Output Torque sensor voltage Min.: 0.0000 V
Max.: 4.9725 V
·

Engine running and steering wheel not being turned (without load): 2.3 to 2.7 V

·

Engine running and steering wheel being turned to the right with vehicle stopped: 2.5 to 4.7 V

·

Engine running and steering wheel being turned to the left with vehicle stopped: 0.3 to 2.5 V


-
Torque Sensor 2 Output Torque sensor voltage Min.: 0.0000 V
Max.: 4.9725 V
·

Engine running and steering wheel not being turned (without load): 2.3 to 2.7 V

·

Engine running and steering wheel being turned to the right with vehicle stopped: 0.3 to 2.5 V

·

Engine running and steering wheel being turned to the left with vehicle stopped: 2.5 to 4.7 V


-
IG ON/OFF Times Number of times of ignition switch ON/OFF after fail detection Min.: 0 times
Max.: 65535 times
- This value indicates the number of times of ignition switch ON/OFF after the latest DTC detection.
Motor Overheat Record Continuous overheat prevention control record Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Motor Lo Power Record PIG power source voltage drop record Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Eng Rev Inter Record Record of engine speed signal interruption Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Spd Sig Invalid Record Record of vehicle speed signal invalid Unrec or Rec Unrec Unrec: Unrecorded
Rec: Recorded
Battery Voltage Lo Record Battery voltage reduction history Min.: 0 times
Max.: 65535 times
0 to 65535 -
Battery Voltage Battery voltage Min.: 0.0 V
Max.: 25.5 V
Ignition switch ON: 9 to 16 V -
PS Assist Signal Power steering assist signal ON or OFF
·

Ignition switch ON: OFF

·

Engine running: ON


-
Motor Overheat Limit Cnt(Normal) Number of times that assist limit was performed according to the estimated temperature of the portion where heat was generated in the power steering ECU assembly and motor coil Min.: 0 times
Max.: 255 times
- -
Assist Limit Cnt(Power Voltage Low) Number of times that assist limit was performed due to battery voltage having dropped to 9 V or below Min.: 0 times
Max.: 255 times
- -
Power Vol Low Prevention Limit Cnt Number of times that assist limit was performed due to battery voltage having dropped to 9.7 V or below Min.: 0 times
Max.: 255 times
- -
Eng Stall/Ready OFF Cnt Number of times that assist limit was performed after the engine stalled and the ignition switch was turned off Min.: 0 times
Max.: 255 times
- -
Motor Overheat Limit Cnt(Motor Overload) Number of times that assist limit was performed to prevent the system from overheating in a case where the motor is overloaded because it is locked due to the steering wheel being turned to the full lock position or a tire hitting a curb Min.: 0 times
Max.: 255 times
- -
DCDC Current Limit Cnt(DCDC Malf) Number of times that the power steering ECU has limited the current to the power steering motor while the DC/DC converter is malfunctioning. Min.: 0 times
Max.: 255 times
- -
Assist Limit Cnt(Vehicle Spd Sig Malf) Number of times that assist power was set to a value suitable for high-speed driving when high speed is detected due to an abnormal vehicle speed signal Min.: 0 times
Max.: 255 times
- -
Battery Voltage Keep Limit Cnt Number of times that the system was limited to conserve battery voltage Min.: 0 times
Max.: 255 times
- -
Assist Limit Record 1 Information of assist limit that was used in the past or is currently in use (latest history) Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep - -
Record 1 Key Cycle Number of times that the ignition switch was turned ON before Assist Limit Record 1 was stored Min.: 0 times
Max.: 65535 times
- -
Record 1 Key Cycle Elapsed Time Period of time that elapsed since the ignition switch was turned ON before Assist Limit Record 1 was stored Min.: 0.0 s
Max.: 53687091.1 s
- -
Assist Limit Record 2 Information of assist limit that was used in the past (second latest history) Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep - -
Record 2 Key Cycle Number of times that the ignition switch was turned ON after Assist Limit Record 2 was stored before Assist Limit Record 1 was stored Min.: 0 times
Max.: 65535 times
- -
Record 2 Key Cycle Elapsed Time Period of time that elapsed since the ignition switch was turned ON before Assist Limit Record 2 was stored Min.: 0.0 s
Max.: 53687091.1 s
- -
Assist Limit Record 3 Information of assist limit that was used in the past (third latest history) Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep - -
Record 3 Key Cycle Number of times that the ignition switch was turned ON after Assist Limit Record 3 was stored before Assist Limit Record 2 was stored Min.: 0 times
Max.: 65535 times
- -
Record 3 Key Cycle Elapsed Time Period of time that elapsed since the ignition switch was turned ON before Assist Limit Record 3 was stored Min.: 0.0 s
Max.: 53687091.1 s
- -
Current Key Cycle Number of times that ignition switch was turned ON Min.: 0 times
Max.: 65535 times
- -
Current Key Cycle Elapsed Time Time elapsed since ignition switch was turned ON Min.: 0.0 s
Max.: 53687091.1 s
- -
The Number of DTCs Number of detected DTCs when freeze frame data stored Min.: 0
Max.: 255
0 to 255 -