HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  SYSTEM DESCRIPTION  


GENERAL


a.

The air conditioning system has the following controls.

Control Outline
Manual Control The air conditioning amplifier assembly controls the damper positions and blower speed in accordance with the positions of the switches (temperature control switch, blower switch, mode control switch and inlet control switch).
Compressor Control Through the calculation of the target evaporator temperature based on various sensor signals, the air conditioning amplifier optimally controls discharge capacity by regulating the opening extent of the compressor solenoid valve.
Defroster Control Defroster control logic is used to improve defroster performance.
Rear Defogger Control When the ignition switch is ON and the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes. However, the operating time of the rear defogger can be extended up to approx. 60 minutes when both of the following requirements are met:
·

Ambient Temperature: 0°C (32°F) or less

·

Vehicle Speed: 37.3 mph (60 km/h) or more


Diagnosis A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier detects a problem with the air conditioning system.



MODE POSITION AND DAMPER OPERATION


a.

Mode Position and Damper Operation

E236745E02
2.115,2.375 1.854,2.594 false 2.604,2.417 2.302,2.844 false 0.635,2.552 0.969,2.094 false 1.729,0.073 2.792,0.313 1.063,0.24 10 false Center Defroster 0.313,0.375 1.229,0.656 0.917,0.281 10 false Side Defroster 0.073,1.073 0.688,1.354 0.615,0.281 10 false Fresh Air 1.188,0.99 2,1.375 0.813,0.385 10 false Recirculation Air 0.563,4.365 1.417,4.583 0.854,0.219 10 false Side Register 6.26,4.365 7.104,4.604 0.844,0.24 10 false Side Register 0.031,2.563 1.219,2.969 1.188,0.406 10 false Blower Motor with Fan Sub-assembly 1.5,2.604 2.167,2.833 0.667,0.229 10 false Evaporator 1.26,2.875 2.521,3.313 1.26,0.438 10 false Heater Radiator Unit Sub-assembly 1.104,1.677 1.24,1.906 0.135,0.229 10 false A 0.802,1.677 0.938,1.906 0.135,0.229 10 false B 2.333,2.104 2.469,2.333 0.135,0.229 10 false C 2.26,1.917 2.396,2.146 0.135,0.229 10 false D 2.323,1.729 2.458,1.958 0.135,0.229 10 false E 1.854,5.51 3.604,5.74 1.75,0.229 10 false Rear Footwell Register Duct 4.979,4.729 6.813,5 1.833,0.271 10 false Front Footwell Register Duct 3.281,4.531 4.667,4.688 1.385,0.156 10 false Front Center Register 3.396,5.094 4.76,5.375 1.365,0.281 10 false Rear Center Register 0.51,4.729 2.292,4.958 1.781,0.229 10 false Front Footwell Register Duct 3.271,0.375 4.198,0.656 0.927,0.281 10 false Side Defroster 2.125,1.031 2.26,1.26 0.135,0.229 10 false F 2.25,0.99 2.385,1.219 0.135,0.229 10 false G 2.406,1.115 2.542,1.344 0.135,0.229 10 false H 3.354,3.792 3.49,4.021 0.135,0.229 10 false J 3.302,3.583 3.438,3.813 0.135,0.229 10 false K 3.719,3.948 3.854,4.177 0.135,0.229 10 false L 3.792,3.813 3.927,4.042 0.135,0.229 10 false M 3.719,4.208 3.854,4.438 0.135,0.229 10 false N 4.313,3.583 4.448,3.813 0.135,0.229 10 false O 4.208,3.771 4.344,4 0.135,0.229 10 false P 2.76,1.635 2.896,1.865 0.135,0.229 10 false Q 2.844,1.813 2.979,2.042 0.135,0.229 10 false R 3.083,1.76 3.219,1.99 0.135,0.229 10 false S 2.823,2.469 2.958,2.698 0.135,0.229 10 false T 2.729,2.76 2.865,2.99 0.135,0.229 10 false U 2.542,2.594 2.677,2.823 0.135,0.229 10 false V 2.438,4.792 2.604,5.021 0.167,0.229 10 false W 2.969,4.698 3.104,4.927 0.135,0.229 10 false Y 2.729,4.667 2.865,4.896 0.135,0.229 10 false X 2.313,1.292 2.448,1.521 0.135,0.229 10 false I

Functions of Main Dampers
Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper FRESH A Allows fresh air to enter.
RECIRC B Causes internal air to recirculate.
Air Mix Control Damper MAX COLD to MAX HOT Temperature Setting C - D - E
T - U - V
Varies the mixture ratio of the warm air and the cool air in order to regulate the temperature continuously between hot and cold.
Air Outlet Control Damper DEF
E264847

F, J, L, P, S, Y Defrosts the windshield through the center defroster, side defroster, and side registers.
FOOT / DEF
E264851

G, J, L, P, Q, X Defrosts the windshield through the center defroster, side defrosters, side registers, and rear center register, while air is also blown out from the front and rear footwell register ducts.
FOOT
E264850

H, J, L, P, Q, X Air blows out of the front and rear footwell register duct, and side registers. In addition, air blows out slightly from the center defroster and side defrosters.
BI-LEVEL
E264849

I, K, N, O, R, X Air blows out of the front and rear center registers, side registers and front and rear footwell registers ducts.
FACE
E264852

I, K, M, O, S, W Air blows out of the front and rear center registers, and side registers.



AIR OUTLETS AND AIRFLOW VOLUME


a.

Air Outlets and Airflow Volume

E236092E02
3.689,2.223 3.833,2.388 0.144,0.165 10 A 5.593,1.808 5.737,1.973 0.144,0.165 10 B 2.247,2.705 2.391,2.87 0.144,0.165 10 B 5.718,4.014 5.862,4.179 0.144,0.165 10 C 5.422,4.122 5.566,4.287 0.144,0.165 10 C 2.526,3.458 2.67,3.623 0.144,0.165 10 D 2.713,0.638 2.857,0.803 0.144,0.165 10 F 1.886,1.746 2.03,1.911 0.144,0.165 10 G 5.162,0.895 5.306,1.06 0.144,0.165 10 G 3.658,4.642 3.802,4.807 0.144,0.165 10 E 5.059,4.236 5.203,4.401 0.144,0.165 10 E 4.53,2.981 4.674,3.147 0.144,0.165 10 D 4.144,2.111 4.288,2.276 0.144,0.165 10 A

MODE Register Footwell Defroster
CTR SIDE RR FR RR CTR SIDE
A B C D E F G
FACE-U*1
E264852

E264853

E264853

E264853

E264858

E264858

E264858

E264858

B/L-U*2
E264849

E264854

E264854

E264854

E264855

E264855

E264858

E264858

FOOT-F*3
E264850

E264858

E264855

E264855

E264854

E264855

E264856

E264856

FOOT-F*4
E264858

E264855

E264855

E264854

E264855

E264856

E264856

F/D
E264851

E264858

E264855

E264855

E264854

E264854

E264854

E264854

DEF
E264847

E264858

E264855

E264858

E264858

E264858

E264857

E264857


·

*1: Air blows out of registers only

·

*2: Regular bi-level mode

·

*3: Regular foot mode (MAX. HOT only)

·

*4: Foot mode with large airflow volume from the rear footwell register ducts (except MAX. HOT)

·

The size of each circle ○ indicates the ratio of airflow volume




PARKING FRESH CONTROL (for RHD)


When 60 seconds have elapsed since the ignition switch has been turned off, the air conditioning amplifier assembly uses control logic which automatically changes the air inlet to FRESH mode to purge undesired odors from the air conditioning unit.

This logic will therefore reduce undesired odors upon starting the air conditioning system.

E279972E14
0.177,0.104 1.115,0.313 0.938,0.208 10 false Timing Chart: 0.188,0.927 1.302,1.365 1.115,0.438 10 false When Last Mode RECIRCULATION 2.021,1.438 3.208,1.667 1.188,0.229 10 false RECIRCULATION 2.625,0.885 3.24,1.094 0.615,0.208 10 false FRESH 2.615,2.698 3.271,2.906 0.656,0.208 10 false FRESH 2.021,3.042 3.208,3.271 1.188,0.229 10 false RECIRCULATION 3.219,3.375 4.385,3.677 1.167,0.302 10 false Ignition Switch off 0.198,2.792 1.271,3.219 1.073,0.427 10 false When Last Mode FRESH 5.615,3.375 6.802,3.615 1.188,0.24 10 false Ignition Switch ON 3.917,0.177 4.469,0.375 0.552,0.198 10 false 60 Sec. 4.646,0.167 6.177,0.417 1.531,0.25 10 false Air Mode When Parked


COMPRESSOR


a.

General:

i.

The compressor is a continuously variable capacity type in which its capacity can be varied in accordance with the cooling load of the air conditioning system.


ii.

The compressor consists of a pulley, shaft, lug plate, swash plate, piston, shoe, crank chamber, cylinder, solenoid valve with built-in Crank chamber to Suction passage (CS) valve, A/C flow sensor, oil separator and variable suction side throttle.


iii.

A solenoid valve is provided to enable the suction pressure to be controlled as desired.


iv.

The Crank chamber to Suction passage (CS) valve, built into the solenoid valve, operates in accordance with the suction pressure.


v.

The oil separator is installed in the refrigerant passage to separate compressor oil from the refrigerant that is discharged. This helps to prevent the compressor oil from flowing into the air conditioning system and reducing cooling effectiveness.



b.

Solenoid Valve Operation:

i.

The crank chamber is connected to the suction passage. A solenoid valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).


ii.

The solenoid valve operates under duty cycle control in accordance with the signals from air conditioning amplifier assembly.


iii.

When the solenoid valve closes (solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure that is applied to the right side of the piston becomes greater than the pressure that is applied to the left side of the piston. This compresses the spring and tilts the swash plate. As a result, the piston stroke increases and the discharge capacity also increases.


iv.

When the solenoid valve opens (solenoid coil is not energized), the difference in pressure disappears. Then, the pressure that is applied to the left side of the piston becomes the same as the pressure that is applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the swash plate. As a result, there is no piston stroke, and the discharge capacity is reduced.



c.

CS Valve Operation:

i.

The CS valve consists of passage A and passage B. If the vehicle is left parked for a long period, refrigerant may accumulate in the crank chamber due to the heat capacity difference.


ii.

The solenoid control valve is controlled by the air conditioning amplifier assembly. While the compressor is operating, the solenoid control valve pushes down the CS valve rod and open passage A.


iii.

Under the above condition, only if the refrigerant accumulates in the crank chamber, the crank chamber pressure will become high. As a result, the bellows will contract because of the pressure difference with its internal pressure (vacuum), and opens passage B.


iv.

This causes the accumulated refrigerant to be drawn in via passage A and B, clearing the accumulated refrigerant earlier and ensuring a more immediate cooling effect.




A/C FLOW SENSOR


The A/C flow sensor, which is mounted on the compressor, is used to detect the amount of refrigerant flow. The A/C flow sensor converts the amount of refrigerant flow that is detected to a voltage value to send it to the air conditioning amplifier assembly. The voltage value sent from the A/C flow sensor changes depending on the amount of refrigerant flow. As the amount of refrigerant flow becomes larger, the voltage becomes lower. As the amount of refrigerant flow becomes smaller, the voltage becomes higher. The air conditioning amplifier assembly supplies 5 V to the A/C flow sensor and monitors changes in the voltage value sent from the A/C flow sensor. The air conditioning amplifier assembly then sends a signal to the ECM via CAN communication to allow the ECM to control the engine speed while the air conditioning is on.


EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)


The evaporator temperature sensor (No. 1 cooler thermistor) detects the temperature of the cool air immediately through the evaporator in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.


BLOWER WITH FAN MOTOR SUB-ASSEMBLY


The blower motor has a built-in blower controller, and is controlled using duty control performed by the air conditioning amplifier assembly.


BUS CONNECTOR (AIR CONDITIONING HARNESS ASSEMBLY)


a.

BUS connectors are used in the wire harness that connects the servo motors to the air conditioning amplifier assembly.

E116948E19
4.917,4.583 5.302,4.583 false 4.448,3.677 4,3.677 false 1.135,3.75 1.135,4.125 false 0.167,1.927 1.135,2.094 0.969,0.167 10 false Bus Connector 2.552,1.938 3.521,2.104 0.969,0.167 10 false Bus Connector 3.01,3.594 3.979,3.76 0.969,0.167 10 false Bus Connector 5.344,4.51 6.313,4.677 0.969,0.167 10 false Bus Connector 0.188,2.094 2.438,2.281 2.25,0.188 10 false (to Air Mix Servo Motor (for Driver)) 2.573,2.094 4.24,2.281 1.667,0.188 10 false (to Air Inlet Servo Motor) 0.229,4.167 2.302,4.406 2.073,0.24 10 false Evaporator Temperature Sensor 3.01,3.781 3.906,4.104 0.896,0.323 10 false (to Air Outlet Servo Motor) 5.354,4.677 6.823,5.021 1.469,0.344 10 false (to Air Mix Servo Motor (for Front Passenger)) 6.042,1.698 7.094,1.885 1.052,0.188 10 false to A/C Amplifier 0.146,0.094 0.854,0.354 0.708,0.26 12 false Example:


b.

Each BUS connector has a built-in communication/driver IC which communicates with the air conditioning amplifier assembly, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness, for a more lightweight construction and a reduced number of wires.

E116949E13
0.109,0.093 1.598,0.27 1.489,0.177 12 w/ BUS Connector: 0.109,2.657 1.754,2.834 1.645,0.177 12 w/o BUS Connector: 0.695,0.575 1.537,0.747 0.842,0.172 10 A/C Amplifier 0.695,3.115 1.537,3.287 0.842,0.172 10 A/C Amplifier 0.9,0.899 2.081,1.059 1.181,0.16 8 Communication Circuit 1.259,1.514 1.586,1.666 0.326,0.153 10 CPU 1.618,3.188 2.147,3.347 0.529,0.159 10 Drive IC 1.618,4.447 2.147,4.606 0.529,0.159 10 Drive IC 0.837,4.096 1.162,4.241 0.325,0.145 10 CPU 3.276,0.257 4.264,0.427 0.987,0.17 10 BUS Connector 4.82,0.139 6.431,0.309 1.611,0.17 10 Communication/Driver IC 5.741,1.464 6.527,1.639 0.786,0.175 10 Servo Motor 5.741,4.028 6.527,4.203 0.786,0.175 10 Servo Motor 4.562,0.752 4.725,0.198 4.725,0.198 4.793,0.198 false 4.408,0.682 4.34,0.341 4.34,0.341 4.293,0.341 false



SERVO MOTOR


The pulse pattern type servo motor consists of a printed circuit board and a servo motor. The printed circuit board has three contact points, and can transmit two ON-OFF signals to the air conditioning amplifier assembly based on the difference of the pulse phases. The BUS connector can detect the damper position and movement direction with these signals.

E116950E21
6.219,1.146 6.094,0.156 false 4.479,1.156 4.542,0.177 false 1.521,1.521 1.521,0.583 1.521,0.583 1.438,0.583 false 1.281,3.25 1.281,4.094 1.281,4.094 1.375,4.094 false 1.156,2.896 0.323,3.781 0.323,3.781 0.323,3.948 false 4.542,0.177 4.656,0.177 false 6.094,0.156 6.188,0.156 false 0.479,0.521 1.417,0.688 0.938,0.167 10 false Contact Points 1.417,4.021 2.813,4.188 1.396,0.167 10 false Printed Circuit Board 0.083,3.948 0.865,4.281 0.781,0.333 10 false Conductive Portion 2.625,1.563 2.75,1.74 0.125,0.177 10 false A 3.042,2.521 3.167,2.698 0.125,0.177 10 false A 3.229,1.104 3.354,1.281 0.125,0.177 10 false A 2.625,1.771 2.75,1.948 0.125,0.177 10 false B 3.042,3.177 3.167,3.354 0.125,0.177 10 false B 3.229,1.667 3.354,1.844 0.125,0.177 10 false B 2.625,1.969 2.958,2.135 0.333,0.167 10 false GND 3.021,1.385 3.354,1.552 0.333,0.167 10 false GND 3.344,2.375 3.5,2.552 0.156,0.177 10 false Hi 3.323,2.688 3.5,2.865 0.177,0.177 10 false Lo 3.344,3.052 3.5,3.229 0.156,0.177 10 false Hi 3.323,3.354 3.5,3.531 0.177,0.177 10 false Lo 4.76,3.917 5.427,4.083 0.667,0.167 10 false 1 Rotation 2.677,0.708 3.656,0.896 0.979,0.188 10 false Contact Points: 4.677,0.104 5.885,0.292 1.208,0.188 10 false Conductive Portion 6.229,0.094 7.156,0.427 0.927,0.333 10 false Printed Circuit Board


AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)


The ambient temperature sensor (thermistor assembly) detects the outside temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.


AIR CONDITIONING PRESSURE SENSOR


The air conditioning pressure sensor detects the refrigerant pressure and outputs it to the air conditioning amplifier assembly in the form of voltage changes.