SFI SYSTEM > DIAGNOSIS SYSTEM |
| EURO-OBD |
![]() |
| M-OBD (except EUROPEAN SPEC) |
![]() |
The emission control system components
The powertrain control components (which affect vehicle emissions)
The computer
In addition, the applicable DTCs are recorded in the ECM memory. If the malfunction does not recur in 3 consecutive trips, the MIL turns off automatically but the DTCs remain recorded in the ECM memory.
| NORMAL MODE AND CHECK MODE |
| 2 TRIP DETECTION LOGIC |
| DLC3 (Data Link Connector 3) |
Check the DLC3 (Click here).
| FREEZE FRAME DATA |
| BATTERY VOLTAGE |
| MIL (Malfunction Indicator Lamp) |
The MIL is illuminated when the ignition switch is turned to ON (the engine is not running).
The MIL should turn off when the engine is started. If the MIL remains illuminated, the diagnosis system has detected a malfunction or abnormality in the system.
| ALL READINESS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Clear the DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the tester on.
Perform the DTC judgment driving pattern to run the DTC judgment.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTCs to be confirmed.
Check the DTC judgment result.
| Tester Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|