DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0712 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic) |
|
| P0713 | ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more. Either of the following conditions is met (1 trip detection logic): |
|
| Condition (A): 394 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less. | ||
| Condition (B): 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (- 20.875°F). |

| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or short circuited |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Remove the TCM from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 17 (E2) - 18 (THO1) | Always | 79 Ω to 156 kΩ |
| 17 (E2) - Body ground and other terminals | Always | 10 kΩ or higher |
| 18 (THO1) - Body ground and other terminals | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | ||
| ||
| 2.INSPECT ATF TEMPERATURE SENSOR |
![]() |
Disconnect the ATF temperature sensor connector from the transmission wire.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E2 - THO1 | Always | 79 Ω to 156 kΩ |
| E2 - Body ground and other terminals | Always | 10 kΩ or higher |
| THO1 - Body ground and other terminals | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | ||
| ||