CHARGING SYSTEM > ON-VEHICLE INSPECTION |
| 1. CHECK BATTERY CONDITION |
Check the battery for damage or deformation. If severe damage, deformation or leakage is found, replace the battery.
Check the electrolyte quantity of each cell.
![]() |
For maintenance-free batteries:
For non-maintenance-free batteries:
Check the voltage.
Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.
Measure the battery voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Positive (+) terminal - Negative (-) terminal | 20°C (68°F) | 12.5 to 12.9 V |
| 2. INSPECT BATTERY TERMINAL |
Check that the battery terminals are not loose or corroded.
If the terminals are corroded, clean them.
| 3. INSPECT FUSE |
Measure the resistance of each fuse for the charging system.
| 4. INSPECT V-RIBBED BELT |
![]() |
Check the belt for wear, cracks or other signs of damage.
| *a | INCORRECT |
![]() |
Check that the belt fits properly in the ribbed grooves.
| *a | CORRECT |
| *b | INCORRECT |
| 5. INSPECT GENERATOR WIRING |
Visually check the generator wiring.
Check that the wiring is in good condition.
| 6. CHECK FOR ABNORMAL NOISE |
Check for abnormal noises from the generator.
Check that no abnormal noises are heard from the generator while the engine is running.
| 7. INSPECT CHARGE WARNING LIGHT CIRCUIT |
Turn the ignition switch to ON. Check that the charge warning light comes on.
Start the engine and check that the light goes off.
If the light does not operate as specified, troubleshoot the charge warning light circuit.
| 8. INSPECT CHARGING CIRCUIT WITHOUT LOAD |
![]() |
Connect a voltmeter and ammeter to the charging circuit as follows.
| *1 | Ammeter |
| *2 | Terminal B |
| *3 | Generator assembly |
| *4 | Voltmeter |
| *5 | Battery |
Disconnect the wire from terminal B of the generator, and then connect it to the negative (-) lead of the ammeter.
Connect the positive (+) lead of the ammeter to terminal B of the generator assembly.
Connect the positive (+) lead of the voltmeter to the positive (+) terminal of the battery.
Ground the negative (-) lead of the voltmeter.
Check the charging circuit.
Keep the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.
| 9. INSPECT CHARGING CIRCUIT WITH LOAD |
With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the "HI" position.
Check the reading on the ammeter.