GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR PULLEY WITH CLUTCH |
![]() |
Hold the generator rotor using SST, and turn the generator pulley with clutch clockwise to check that the outer ring locks.
| *a | Free |
| *b | Lock |
| 2. INSPECT GENERATOR DRIVE END FRAME BEARING |
![]() |
Check that the bearing is not rough or worn and that it rotates smoothly.
| 3. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the brush length.
| *a | Length |
| 4. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Check that the generator rotor bearing is not rough or worn.
If the result is not as specified, replace the generator rotor assembly.
![]() |
Check the rotor for an open circuit.
| *1 | Slip Ring |
| *2 | Ohmmeter |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Slip ring | Approx. 20°C (68°F) | 2.3 to 2.7 Ω |
![]() |
Check if the rotor is grounded.
| *1 | Slip Ring |
| *2 | Ohmmeter |
| *3 | Rotor |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Rotor | Always | 10 kΩ or higher |
Check the slip ring diameter.
![]() |
Using a vernier caliper, measure the diameter of each slip ring.
| *a | Diameter |