Home › Power Source / Network ยท 2AR-FE BATTERY / CHARGING › GENERATOR

GENERATOR > REMOVAL

for Preparation Click here



1. PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (Click here).



2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



3. REMOVE V-RIBBED BELT
(Click here).


4. REMOVE GENERATOR ASSEMBLY


    A254984
  1. Disconnect the generator connector.

  1. Remove the terminal cap.

  1. Remove the nut and disconnect the generator wire.

  1. Remove the bolt and wire harness clamp bracket.



    A254985
  1. Remove the 2 bolts and generator.