THERMOSTAT > INSPECTION |
| 1. INSPECT THERMOSTAT |
![]() |
The valve opening temperature is inscribed on the thermostat.
![]() |
Immerse the thermostat in water, and then gradually heat the water.
Check that the valve of the thermostat opens at the specified temperature.
![]() |
Check the valve lift.
| *a | Valve Lift |
Check that the valve is fully closed when the thermostat is at a low temperature (below 77°C (171°F)).
If the valve is not fully closed, replace the thermostat.