GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR PULLEY WITH CLUTCH |
![]() |
Hold the center of the generator pulley with clutch, and confirm that the outer ring turns counterclockwise and does not turn clockwise.
| *a | Free |
| *b | Lock |
| 2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the length of the exposed brushes.
| *a | Length |
| 3. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Check that the generator rotor bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
Check the generator rotor assembly for an open circuit.
![]() |
Using an ohmmeter, measure the resistance between the slip rings.
| *1 | Ohmmeter |
| *2 | Slip Ring |
| Tester Connection | Specified Condition |
| Slip ring | 2.3 to 2.7 Ω |
Check the generator rotor assembly for a short to ground.
![]() |
Using an ohmmeter, measure the resistance between the slip ring and rotor.
| *1 | Ohmmeter |
| *2 | Rotor |
| *3 | Slip Ring |
| Tester Connection | Specified Condition |
| Slip ring - Rotor | 10 MΩ or higher |
![]() |
Using a vernier caliper, measure the slip ring diameter.
| *a | Diameter |
| 4. INSPECT GENERATOR DRIVE END FRAME BEARING |
![]() |
Check that the generator drive end frame bearing is not rough or worn.