Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR

AIR CONDITIONING PRESSURE SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT AIR CONDITIONING PRESSURE SENSOR
  1. Check the wire harness.

    1. Disconnect the A55 air conditioning pressure sensor connector.

    2. Disconnect the I77 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      A55-1 (-) - I77-13 (SG-2)
      Always
      Below 1 Ω
      A55-2 (PR) - I77-9 (PRE)
      Always
      Below 1 Ω
      A55-3 (+) - I77-10 (S5-3)
      Always
      Below 1 Ω
      A55-1 (-) - Body ground
      Always
      10 kΩ or higher
      A55-2 (PR) - Body ground
      Always
      10 kΩ or higher
      A55-3 (+) - Body ground
      Always
      10 kΩ or higher

      If the resistance is not as specified, repair the wire harness.

    4. Reconnect the I77 air conditioning amplifier assembly connector.

    5. Turn the ignition switch to ON.

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch condition
      Specified Condition
      A55-3 (+) - Body ground
      Ignition switch ON
      4.75 to 5.25 V

      If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.
      Text in Illustration 
      *a
      Front view of wire harness connector
      (to Air Conditioning Pressure Sensor)



  1. Check the air conditioning pressure sensor.

    1. Connect the connector to the air conditioning pressure sensor.

    2. Install a manifold gauge set.

    3. Warm up the engine.

    4. Turn the A/C switch on.



    5. E227427E24
    6. Measure the voltage according to the value(s) in the table below.

      HINT:
      Check from the rear of the connector while it is connected to the air conditioning amplifier.

      Standard Voltage:
      Tester Connection
      Condition
      Specified Condition
      I77-9 (PRE) - I77-13 (SG-2)
      Refrigerant pressure:
      (less than 3025 kPa (30.9 kgf*cm2, 439 psi) and more than 176 kPa (1.8 kgf*cm2, 25 psi)
      0.50 to 4.80 V

      If the voltage is not as specified, replace the air conditioning pressure sensor.
      Text in Illustration 
      *a
      Component with harness connected
      (Air Conditioning Amplifier)