COMPRESSOR (for 2AR-FE) > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL LEVEL |
When replacing the compressor with a new one:
![]() |
Remove the drain bolt (washer).
| *1 | Drain bolt (washer) |
![]() |
Gradually discharge the inert gas from the service valve. Then drain the following amount of oil from the new compressor before installation so that the amount of oil contained in it is the same as that in the compressor to be replaced.
| *1 | Removed Compressor |
| *2 | Amount of oil drain from removed compressor |
| *3 | Amount of oil remaining in the reserve chamber (60 cc (3.66 fl.oz)) |
Install the drain bolt (washer).
If draining the oil is difficult, drain the oil using the following procedure:
Remove the suction seal cap.
![]() |
Lightly shake the compressor with the suction port facing down, and drain the oil (*1).
![]() |
With the DL pulley facing down, rotate the pulley in the direction shown by the arrow 10 times at a rate of approximately once every 2 seconds (*2).
![]() |
Rotate the pulley once in the direction shown by the arrow while quickly turning the compressor so the pulley is up (*3).
Proceed with the above procedure (*1) and drain the oil (*4).
Drain the oil by repeating the procedures above approximately 5 times (from (*2) to (*4)).
| 2. INSTALL COMPRESSOR ASSEMBLY WITH PULLEY |
![]() |
Using an E8 "TORX" socket, temporarily install the compressor assembly with pulley with the 2 stud bolts.
![]() |
Install the compressor assembly with pulley with the 2 bolts and 2 nuts.
| 3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the compressor assembly with pulley.
Install the O-ring onto the No. 1 cooler refrigerant discharge hose.
Install the No. 1 cooler refrigerant discharge hose onto the compressor assembly with pulley with the bolt.
Connect the 2 connectors.
Install the bolt.
| 4. CONNECT NO. 1 COOLER REFRIGERANT SUCTION HOSE |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the compressor assembly with pulley.
Install the O-ring onto the No. 1 cooler refrigerant suction hose.
Install the No. 1 cooler refrigerant suction hose onto the compressor assembly with pulley with the bolt.
Connect the 2 connectors.
Install the bolt.
| 5. INSTALL V-RIBBED BELT |
![]() |
Set the V-ribbed belt onto each part as shown in the illustration except the water pump pulley.
| *1 | Crankshaft |
| *2 | Tensioner |
| *3 | Generator |
| *4 | Water Pump |
| *5 | Cooler Compressor |
Loosen the V-ribbed belt by turning the belt tensioner clockwise.
Set the V-ribbed belt onto the water pump pulley.
| 6. INSTALL FRONT FENDER APRON SEAL RH |
| 7. INSTALL RADIATOR ASSEMBLY |
| 8. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
Perform vacuum purging using a vacuum pump or appropriate equipment.
Charge the air conditioning system with refrigerant.

| *a | Sub-cool System | *b | High Pressure |
| *c | Refrigerant Amount | *d | Standard charge amount |
| *e | Charge additional 100 g (3.5 oz.) | *f | Point where bubbles disappear |
| *g | Mean value in proper range | *h | Overcharged |
| 9. WARM UP ENGINE |
Keep the A/C switch on for at least 2 minutes to warm up the compressor.
| 10. INSPECT FOR REFRIGERANT LEAK |
After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
| *1 | Halogen Leak Detector |
| *a | Inspect for Leak |
![]() |
Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
| *1 | Halogen Leak Detector |
| *2 | Drain Hose |
If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.
Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.