DTC P0660 Intake Manifold Tuning Valve Control Circuit / Open (Bank 1) |

| *1 | Intake Air Control Valve Open | *2 | Intake Air Control Valve Closed |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0660 | The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
|
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE VSV FOR INTAKE CONTROL) |
![]() |
Disconnect the vacuum hose from port F on the vacuum switching valve assembly (for acoustic control induction system).
| *1 | Port F |
| *2 | Port E |
| *a | ON |
| *b | OFF |
| *c | Air |
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Intake Control.
Operate the vacuum switching valve assembly (for acoustic control induction system) check the air flow.
| Activate the VSV for Intake Control | Specified Condition |
| ON | Air from port E flows out through port F |
| OFF | Air from port E flows out through air filter |
| Result | Proceed to |
| Abnormal | A |
| Normal | B |
|
| ||||
| A | |
| 2.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM) |
Inspect the vacuum switching valve assembly (for acoustic control induction system) (Click here).
|
| ||||
| OK | |
| 3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE (FOR ACOUSTIC CONTROL INDUCTION SYSTEM)) |
![]() |
Disconnect the vacuum switching valve assembly (for acoustic control induction system) connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| E45-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Vacuum Switching Valve Assembly (for Acoustic Control Induction System)) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR ACOUSTIC CONTROL INDUCTION SYSTEM) - ECM) |
Disconnect the vacuum switching valve assembly (for acoustic control induction system) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E45-1 (ACIS) - E26-69 (ACIS) | Always | Below 1 Ω |
| E45-1 (ACIS) or E26-69 (ACIS) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - VACUUM SWITCHING VALVE (FOR ACOUSTIC CONTROL INDUCTION SYSTEM)) |
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the vacuum switching valve assembly (for acoustic control induction system) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1A-8 - E45-2 (+B) | Always | Below 1 Ω |
| 1A-8 or E45-2 (+B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||