Home › General › SPECIFICATIONS › 2AR-FE INTAKE / EXHAUST

2AR-FE INTAKE / EXHAUST > SERVICE DATA



VACUUM SWITCHING VALVE (for ACIS) 
VACUUM SWITCHING VALVE
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
37 to 44 Ω
1 - Valve body
Always
10 kΩ or higher
2 - Valve body

EXHAUST PIPE 
Compression spring
Front exhaust pipe assembly x Exhaust manifold converter sub-assembly
Minimum length: 40.5 mm (1.59 in.)
Compression spring
Front exhaust pipe assembly x Tail exhaust pipe assembly
Minimum length: 38.5 mm (1.52 in.)