Home › Drivetrain · U660E AUTOMATIC TRANSMISSION / TRANSAXLE › SHIFT LEVER

SHIFT LEVER > INSPECTION

for Preparation Click here



1. INSPECT LOWER SHIFT LEVER ASSEMBLY


    C239819E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    5 (IG) - Body ground
    Engine switch on (IG)
    11 to 14 V
    Engine switch off
    Below 1 V
    4 (STP) - Body ground
    Brake pedal depressed
    11 to 14 V
    Brake pedal released
    Below 1 V

    Text in Illustration 
    *a
    Component with harness connected
    (Shift Lock Control ECU)

    HINT:
    Do not disconnect the shift lock control unit assembly connector.



    C239819E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (E) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *a
    Component with harness connected
    (Shift Lock Control ECU)

    HINT:
    Do not disconnect the shift lock control unit assembly connector.



  1. Inspect shift lock solenoid



      C239826
    1. Disconnect the shift lock solenoid connector.



    2. C197452E09
    3. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

      Standard Resistance:
      Tester Connection
      Shift Lever Position
      Specified Condition
      4 (P) - 3 (E2)
      P
      10 kΩ or higher
      4 (P) - 3 (E2)
      Other than P
      Below 1 Ω

      Text in Illustration 
      *a
      Front view of wire harness connector
      (to Shift Lock Solenoid)
      1. If the result is not as specified, replace the shift lock control unit assembly.
      2. If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 (SLS+) - 2 (SLS-)
      Always
      112 Ω

      1. If the result is not as specified, replace the shift lock control unit assembly.
      2. If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.



2. INSPECT TRANSMISSION CONTROL SWITCH


    C239095E08
  1. Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    4 (IG) - 5 (S)
    Shift lever in S, "+" or "-"
    Below 1 Ω
    Shift lever not in S, "+" or "-"
    10 kΩ or higher
    3 (SFTU) - 2 (E)
    Shift lever held in "+"
    (Up-shift)
    Below 1 Ω
    Shift lever not held in "+"
    10 kΩ or higher
    1 (SFTD) - 2 (E)
    Shift lever held in "-"
    (Down-shift)
    Below 1 Ω
    Shift lever not held in "-"
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Control Switch)
    If the resistance value is not as specified, replace the shift lock control unit assembly.