Home › Engine / Hybrid System ยท 2AR-FE › EMISSION CONTROL › CANISTER

CANISTER > INSPECTION

for Preparation Click here



1. INSPECT CHARCOAL CANISTER ASSEMBLY
  1. Visually check the charcoal canister.

    1. Visually check the charcoal canister for cracks or damage.

      HINT:
      If cracks or damage are found, replace the charcoal canister assembly.



  1. Check charcoal canister airflow.



      A255922E01
    1. Using a vacuum pump, check that air flows through the canister according to the instructions below.

      Standard:
      Measurement Condition
      Specified Condition
      Block port B and C and apply 2 kPa (15 mmHg, 0.591 in.Hg) of vacuum into port A.
      There are no leaks.
      Block port C and apply 2 kPa (15 mmHg, 0.591 in.Hg) of vacuum into port A.
      Air is sucked into port B.
      Block port C and blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into port A.
      Air comes out of port B.
      Blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into port A.
      Air comes out of port B and C.

      HINT:
      If the standard is not as specified, replace the charcoal canister assembly.



2. CLEAN FILTER IN CANISTER


    A256493E01
  1. Clean the filter by blowing 5 kPa (0.1 kgf/cm2, 0.7 psi) of compressed air into port A while holding port B closed.
    Text in Illustration 
    *a
    Air

    NOTICE:
    1. Make sure to clean the filter using only air, do not use gasoline or any other means.
    2. Do not disassemble the charcoal canister assembly.