Home › Engine / Hybrid System · 2GR-FE › ENGINE CONTROL › AIR FUEL RATIO SENSOR

AIR FUEL RATIO SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AIR FUEL RATIO SENSOR (for Bank 1)


    A183494E32
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HA1A) - 2 (+B)
    20°C (68°F)
    1.6 to 3.2 Ω
    1 (HA1A) - 4 (A1A-)
    -
    10 kΩ or higher
    Text in Illustration 
    *a
    Component without harness connected
    (Air Fuel Ratio Sensor)

    If the result is not as specified, replace the air fuel ratio sensor.



2. INSPECT AIR FUEL RATIO SENSOR (for Bank 2)


    A183494E33
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HA2A) - 2 (+B)
    20°C (68°F)
    1.6 to 3.2 Ω
    1 (HA2A) - 4 (A2A-)
    -
    10 kΩ or higher
    Text in Illustration 
    *a
    Component without harness connected
    (Air Fuel Ratio Sensor)

    If the result is not as specified, replace the air fuel ratio sensor.