Home › Engine / Hybrid System ยท 1AZ-FE › EMISSION CONTROL › CANISTER

CANISTER > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT CHARCOAL CANISTER ASSEMBLY
  1. Visually check the charcoal canister assembly.

    1. Visually check the charcoal canister assembly for cracks or damage.

      HINT:
      If cracks or damage are found, replace the charcoal canister assembly.



  1. Check charcoal canister assembly operation under positive pressure.



      A255917E01
    1. Disconnect the vent line hose from the charcoal canister assembly. Close the vent line hose using a hose plug or a similar part.
      Text in Illustration 
      *1
      Vent Line Hose
      *2
      Test Hose
      *a
      Air

    2. Connect a test hose to the charcoal canister assembly.

    3. Blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into the hose.

      Standard:
      Air can be blown through the canister.

      HINT:
      If the standard is not as specified, replace the charcoal canister assembly.



  1. Check charcoal canister assembly operation under vacuum.

    1. Disconnect the vent line hose from the charcoal canister assembly. Close the vent line hose using a hose plug or a similar part.

    2. Connect a test hose to the charcoal canister assembly.

    3. Connect a vacuum pump to the test hose.



    4. A255918E01
    5. Using the vacuum pump, apply vacuum and check the gauge.
      Text in Illustration 
      *1
      Vent Line Hose
      *2
      Test Hose

      Standard:
      The vacuum pump gauge does not move from its initial position.

      HINT:
      1. The gauge may move when applying vacuum. If the gauge quickly returns to its initial position, the charcoal canister assembly is operating normally.
      2. If the standard is not as specified, replace the charcoal canister assembly.

  1. Check for clogs in the air filter (when not using the intelligent tester).

    1. Disconnect the vent line hose from the charcoal canister assembly. Close the vent line hose using a hose plug or a similar part.

    2. Connect a test hose to the charcoal canister assembly.

    3. Connect a vacuum pump to the test hose.

    4. Start the engine.

    5. Warm up the engine.

    6. After warm-up, idle the engine for 15 minutes and check the vacuum pump gauge.

      Standard:
      The vacuum pump gauge does not move from its initial position.

      HINT:
      The gauge may move when the purge VSV opens to vacuum. If the gauge quickly returns to its initial position, the charcoal canister assembly is operating normally.

  1. Check for clogs in the air filter (when using the intelligent tester).

    HINT:
    When performing an Active Test of the purge VSV using the intelligent tester, it is not necessary to warm-up and idle the engine for 15 minutes.


    1. Disconnect the vent line hose from the charcoal canister assembly. Close the vent line hose using a hose plug or a similar part.

    2. Connect a test hose to the charcoal canister assembly.

    3. Connect a vacuum pump to the test hose.

    4. Connect the intelligent tester to the DLC3.

    5. Start the engine.

    6. Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Evap Control.

    7. Perform the Active Test with the engine idling.

      Standard:
      The vacuum pump gauge does not move from its initial position.

      HINT:
      The gauge may move when the purge VSV opens to vacuum. If the gauge quickly returns to its initial position, the charcoal canister assembly is operating normally.