LIGHTING SYSTEM > Hazard Warning Switch Circuit |

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
Read the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Hazard Flasher Switch | Hazard switch signal/ON or OFF | ON: Hazard switch on OFF: Hazard switch off | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD SWITCH) |
![]() |
Remove the air conditioning control assembly (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 4 (HAZ) - 6 (GND) | Hazard switch on | Below 1 Ω |
| 4 (HAZ) - 6 (GND) | Hazard switch off | 10 kΩ or higher |
| *a | Component without harness connected (Air Conditioning Control Assembly) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - COMBINATION METER ASSEMBLY) |
Disconnect the I17 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I56-4 (HAZ) - I17-5 (HAZ) | Always | Below 1 Ω |
| I56-4 (HAZ) - Body ground | Always | 10 kΩ or higher |
| I56-6 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||