Home › Vehicle Interior › HEATING / AIR CONDITIONING › COOLER EXPANSION VALVE

COOLER EXPANSION VALVE > INSTALLATION

for Preparation Click here




1. INSTALL COOLER EXPANSION VALVE
  1. Apply sufficient compressor oil to 2 new O-rings and the fitting surfaces of the cooler expansion valve.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the 2 new O-rings to the No. 1 cooler evaporator sub-assembly.

  1. Using a 4 mm hexagon wrench, install the new cooler expansion valve with the 2 hexagon bolts.

    Torque:
    3.5 N*m{ 36 kgf*cm , 31 in.*lbf }



2. CONNECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
  1. Remove the vinyl tape from the pipe.

  1. Sufficiently apply compressor oil to a new O-ring and fitting surface of the air conditioning tube and accessory assembly.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the air conditioner tube and accessory assembly.

  1. Install the air conditioner tube and accessory assembly.



3. CONNECT SUCTION PIPE SUB-ASSEMBLY
  1. Remove the vinyl tape from the pipe.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the suction pipe sub-assembly.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the suction pipe sub-assembly.



    E227143
  1. Move the hook connector in the direction indicated by the arrow in the illustration.

  1. Insert the pipe joint into the fitting hole securely and tighten a new bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. INSTALL FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY (for LHD)
  1. Install the front outer cowl top panel sub-assembly with the 10 bolts.

    Torque:
    10 N*m{ 102 kgf*cm , 7 ft.*lbf }

  1. Engage the 2 clamps to install the wire harness to the front outer cowl top panel sub-assembly.



5. INSTALL FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY (for RHD)
  1. Install the front outer cowl top panel sub-assembly with the 10 bolts.

    Torque:
    10 N*m{ 102 kgf*cm , 7 ft.*lbf }

  1. Engage the 2 clamps to install the wire harness to the front outer cowl top panel sub-assembly.



6. INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
(Click here)


7. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
  1. Perform vacuum purging using a vacuum pump or appropriate equipment.



  1. Charge the air conditioning system with refrigerant.

    Refrigerant type:
    HFC-134a (R134a)



    E143108E11


    Text in Illustration 
    *a
    Sub-cool System
    *b
    High Pressure
    *c
    Refrigerant Amount
    *d
    Standard charge amount
    *e
    Charge additional 100 g (3.5 oz.)
    *f
    Point where bubbles disappear
    *g
    Mean value in proper range
    *h
    Overcharged

    Standard charge amount:
    450 to 550g (15.9 to 19.4oz.)

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    NOTICE:
    1. Do not turn the A/C switch on before charging the air conditioning system with refrigerant. Doing so may cause the compressor to work without refrigerant, resulting in overheating of the compressor.
    2. The refrigerant amount should be checked by quantity (weight).

    HINT:
    Ensure that sufficient refrigerant is available to recharge the system when using a refrigerant recovery unit. Refrigerant recovery units are not always able to recover 100% of the refrigerant from an air conditioning system.



8. WARM UP ENGINE
  1. Keep the A/C switch on for at least 2 minutes to warm up the compressor.

    NOTICE:
    To prevent damage to the compressor, be sure to warm up the compressor when turning the air conditioning on after removing and installing air conditioning system lines (including the compressor).



9. INSPECT FOR REFRIGERANT LEAK
  1. After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.

  1. Carry out the test under the following conditions:

    1. Ignition switch off.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases which are not refrigerant, such as gasoline vapor and exhaust gas).
    3. Repeat the inspection 2 or 3 times.
    4. Measure the pressure to make sure that there is some refrigerant remaining in the air conditioning system.
      Pressure when the compressor is off: approx. 392 to 588 kPa (3.9 to 5.9 kgf/cm2, 57 to 85 psi)



    I042222E40
  1. Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *a
    Inspect for Leak



    N014519E08
  1. Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *2
    Drain Hose

    HINT:
    1. After the blower motor has stopped, leave the cooling unit for more than 15 minutes.
    2. Bring the halogen leak detector sensor under the drain hose.
    3. When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to volatile gases. If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow checking for leaks.

  1. If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.

  1. Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.

    HINT:
    When checking for leaks, the presence of oily dirt at a joint can indicate a leak.