COOLER EXPANSION VALVE > INSTALLATION |
| 1. INSTALL COOLER EXPANSION VALVE |
Apply sufficient compressor oil to 2 new O-rings and the fitting surfaces of the cooler expansion valve.
Install the 2 new O-rings to the No. 1 cooler evaporator sub-assembly.
Using a 4 mm hexagon wrench, install the new cooler expansion valve with the 2 hexagon bolts.
| 2. CONNECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY |
Remove the vinyl tape from the pipe.
Sufficiently apply compressor oil to a new O-ring and fitting surface of the air conditioning tube and accessory assembly.
Install the O-ring to the air conditioner tube and accessory assembly.
Install the air conditioner tube and accessory assembly.
| 3. CONNECT SUCTION PIPE SUB-ASSEMBLY |
Remove the vinyl tape from the pipe.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the suction pipe sub-assembly.
Install the O-ring to the suction pipe sub-assembly.
![]() |
Move the hook connector in the direction indicated by the arrow in the illustration.
Insert the pipe joint into the fitting hole securely and tighten a new bolt.
| 4. INSTALL FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY (for LHD) |
Install the front outer cowl top panel sub-assembly with the 10 bolts.
Engage the 2 clamps to install the wire harness to the front outer cowl top panel sub-assembly.
| 5. INSTALL FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY (for RHD) |
Install the front outer cowl top panel sub-assembly with the 10 bolts.
Engage the 2 clamps to install the wire harness to the front outer cowl top panel sub-assembly.
| 6. INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY |
| 7. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
Perform vacuum purging using a vacuum pump or appropriate equipment.
Charge the air conditioning system with refrigerant.

| *a | Sub-cool System | *b | High Pressure |
| *c | Refrigerant Amount | *d | Standard charge amount |
| *e | Charge additional 100 g (3.5 oz.) | *f | Point where bubbles disappear |
| *g | Mean value in proper range | *h | Overcharged |
| 8. WARM UP ENGINE |
Keep the A/C switch on for at least 2 minutes to warm up the compressor.
| 9. INSPECT FOR REFRIGERANT LEAK |
After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
| *1 | Halogen Leak Detector |
| *a | Inspect for Leak |
![]() |
Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
| *1 | Halogen Leak Detector |
| *2 | Drain Hose |
If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.
Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.