REFRIGERANT LINE > INSTALLATION |
| 1. INSTALL PIPING CLAMP |
Remove the vinyl tape from the open ends of the suction pipe sub-assembly and suction hose sub-assembly.
![]() |
Install a new piping clamp onto the suction hose sub-assembly.
| *1 | Piping Clamp |
| *2 | Groove |
| *3 | Suction Hose Sub-assembly |
Thoroughly coat 2 new O-rings and the contact surface of the suction hose sub-assembly with compressor oil (ND-OIL8).
Install the 2 O-rings onto the suction hose sub-assembly.
![]() |
Engage the suction tube sub-assembly and suction hose sub-assembly by matching the alignment marks.
| *1 | Large Diameter Section of Piping Clamp |
| *2 | Alignment Mark |
![]() |
Securely insert the piping clamp to the point where the large diameter section of the piping clamp is covered by the suction pipe sub-assembly.
| *1 | Large Diameter Section of Piping Clamp |
| 2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
Perform vacuum purging using a vacuum pump or appropriate equipment.
Charge the air conditioning system with refrigerant.

| *a | Sub-cool System | *b | High Pressure |
| *c | Refrigerant Amount | *d | Standard charge amount |
| *e | Charge additional 100 g (3.5 oz.) | *f | Point where bubbles disappear |
| *g | Mean value in proper range | *h | Overcharged |
| 3. WARM UP ENGINE |
Keep the A/C switch on for at least 2 minutes to warm up the compressor.
| 4. INSPECT FOR REFRIGERANT LEAK |
After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
| *1 | Halogen Leak Detector |
| *a | Inspect for Leak |
![]() |
Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
| *1 | Halogen Leak Detector |
| *2 | Drain Hose |
If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.
Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.