REMOTE ENGINE STARTER SYSTEM > TERMINALS OF ECU |
| CHECK REMOTE ENGINE STARTER ECU |
Disconnect the I141 remote engine starter ECU connector.

Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| I141-1 (RSIG) - Body ground | Y - Body ground | IG power supply | Engine switch off | Below 1 V |
| I141-1 (RSIG) - Body ground | Y - Body ground | IG power supply | Engine switch on (IG) | 11 to 14 V |
| I141-5 (RSLP) - Body ground | P - Body ground | Remote engine starter ECU input signal | Remote engine starter function operating | Below 1.5 V |
| I141-10 (R+B) - Body ground | W - Body ground | +B power supply | Always | 11 to 14 V |
| I141-19 (RGN1) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the I141 remote engine starter ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| I141-3 (BRX) - Body ground | R - Body ground | Accessory BERKES SRX signal | Remote engine starter or remote engine stop functions operating | Pulse generation |
| I141-4 (BTX) - Body ground | G - Body ground | Accessory BERKES STX signal | Remote engine starter or remote engine stop functions operating | Pulse generation |
| I141-16 (RESD) - Body ground | B - Body ground | Remote engine starter diagnosis input signal | Diagnostic mode entered | Below 1 V |