1. INSPECT CRANK POSITION SENSOR
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Temperature
    Specified Condition
    Cold
    1630 to 2740 Ω
    Hot
    2065 to 3225 Ω

    HINT:
    "Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122 °F) and "Hot" is from 50 to 100°C (122 to 212°F).
    If the resistance is not as specified, replace the crank position sensor.