Home › Drivetrain · U660E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid temperature into a resistance value for use by the TCM.
G031389E14
The TCM applies a voltage to the temperature sensor through terminal THO1 of the TCM.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The TCM calculates the fluid temperature based on the voltage signal.

DTC No.
DTC Detection Condition
Trouble Area
P0712
ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic)
  1. Short in ATF temperature sensor circuit
  2. Transmission wire
  3. ATF temperature sensor
  4. TCM
P0713
ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more. Either of the following conditions is met (1 trip detection logic):
  1. Open in ATF temperature sensor circuit
  2. Transmission wire
  3. ATF temperature sensor
  4. TCM
Condition (A): 394 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
Condition (B): 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (- 20.875°F).

MONITOR DESCRIPTION

These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor circuit. The automatic transmission fluid (ATF) temperature sensor converts ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the TCM interprets this as a fault in the ATF sensor or wiring. The TCM will turn on the MIL and store the DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the Techstream display.


MONITOR STRATEGY


Related DTCs
P0712: ATF temperature sensor/Range check (Low resistance)
P0713: ATF temperature sensor/Range check (High resistance)
Required sensors/Components
ATF temperature sensor (TFT sensor)
Frequency of operation
Continuous
Duration
0.5 sec.
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


  1. P0712: Range check (Low resistance) 
    The monitor will run whenever these DTCs are not present.
    None
    Battery voltage
    8 V or more
    Engine switch
    on (IG)
P0713: Range check (High resistance)
  1. One of the following conditions is met: Condition (A) or (B)

    Condition (A) 
    Engine coolant temperature (ECT) or intake air temperature (IAT) at engine start
    -29.375°C (-20.875°F) or less
    Time after engine start
    394 seconds or more
    ECT sensor circuit fail (P0115, P0117, P0118)
    Not detected
    IAT sensor circuit fail (P0112, P0113)
    Not detected

    Condition (B) 
    Engine coolant temperature (ECT) or intake air temperature (IAT) at engine start
    More than -29.375°C (-20.875°F)
    Time after engine start
    10 seconds or more
    ECT sensor circuit fail (P0115, P0117, P0118)
    Not detected
    IAT sensor circuit fail (P0112, P0113)
    Not detected

TYPICAL MALFUNCTION THRESHOLDS


P0712: Range check (Low resistance) 
ATF (TFT ) sensor resistance
Less than 79 Ω

P0713: Range check (High resistance) 
ATF (TFT ) sensor resistance
More than 156 kΩ

COMPONENT OPERATING RANGE


ATF (TFT ) sensor resistance
79 to 156 kΩ

WIRING DIAGRAM


C133262E09


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.
  2. Turn the engine switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the engine switch on (IG).
  5. Turn the Techstream on.
  6. Enter the following menus: Powertrain / ECT / Data List.
  7. According to the display on the Techstream, read the Data List.

    TCM 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 1
    ATF temperature sensor value/
    Min.: -40°C (-40°F)
    Max.: 215°C (419°F)
    1. After stall speed test: Approximately 80°C (176°F)
    2. While engine is cold:
      Equal to ambient temperature
    If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or short circuited

    HINT:
    When DTC P0712 is output and the Techstream indicates 150°C (302°F) or more, there is a short circuit.
    When DTC P0713 is output and the Techstream indicates -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal THO1 (OT) and body ground.


    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    If the circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.
    It is not necessary to inspect the circuit when P0711 is set.

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)


    C133212E50
  1. Remove the TCM from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    17 (E2) - 18 (THO1)
    Always
    79 Ω to 156 kΩ
    17 (E2) - Body ground and other terminals
    Always
    10 kΩ or higher
    18 (THO1) - Body ground and other terminals
    Always
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

    ATF Temperature
    Specified Condition
    10°C (50°F)
    5 to 8 kΩ
    25°C (77°F)
    2.5 to 4.5 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ

Text in Illustration 
*a
Component without harness connected
(Transmission Wire)


NG
Go to step 2
OK

REPLACE TCM (Click here)  

2.INSPECT ATF TEMPERATURE SENSOR


    C133224E05
  1. Disconnect the ATF temperature sensor connector from the transmission wire.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E2 - THO1
    Always
    79 Ω to 156 kΩ
    E2 - Body ground and other terminals
    Always
    10 kΩ or higher
    THO1 - Body ground and other terminals
    Always
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

    ATF Temperature
    Specified Condition
    10°C (50°F)
    5 to 8 kΩ
    25°C (77°F)
    2.5 to 4.5 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



NG
REPLACE ATF TEMPERATURE SENSOR ASSEMBLY (Click here)
OK

REPLACE TRANSMISSION WIRE (Click here)