DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2759 | Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic). |
|
| Related DTCs | P2759: Shift solenoid valve SLU/Range check |
| Required sensors/Components | Shift solenoid valve SLU |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Ignition switch | ON |
| Starter | OFF |
| Battery voltage | 12 V or more |
| Battery voltage | 10 V or more and less than 12 V |
| CPU commanded duty | Less than 75% |
| Output duty cycle | 100% or more |
| Output duty cycle | More than 3% and less than 100% |

| 1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLU CIRCUIT) |
![]() |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Condition | Condition | Specified Condition |
| E26-7 (SLU+) - E26-6 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| E26-7 (SLU+) - Body ground and other terminals | Always | 10 kΩ or higher |
| E26-6 (SLU-) - Body ground and other terminals | Always | 10 kΩ or higher |
| *a | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR) |
Disconnect the harness connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Condition | Condition | Specified Condition |
| E26-7 (SLU+) - E8-14 (SLU+) | Always | Below 1 Ω |
| E26-6 (SLU-) - E8-5 (SLU-) | Always | Below 1 Ω |
| E26-7 (SLU+) or E8-14 (SLU+) - Body ground and other terminals | Always | 10 kΩ or higher |
| E26-6 (SLU-) or E8-5 (SLU-) - Body ground and other terminals | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT TRANSMISSION WIRE (SLU) |
![]() |
Remove the wiring harness connector from the automatic transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-11 (SLU+) - A-5 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| A-11 (SLU+) - Body ground and other terminals | Always | 10 kΩ or higher |
| A-5 (SLU-) - Body ground and other terminals | Always | 10 kΩ or higher |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | ||
| ||
| 4.INSPECT SHIFT SOLENOID VALVE SLU |
![]() |
Remove shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
| *1 | Shift Solenoid Valve SLU |
|
| ||||
| OK | ||
| ||