OCCUPANT CLASSIFICATION SYSTEM > INITIALIZATION |
| ZERO POINT CALIBRATION AND SENSITIVITY CHECK |
Zero point calibration and sensitivity check procedure
Check that both of the following conditions are met:
Adjust the seat position according to the table below.
| Adjustment Item | Position |
| Slide Direction | Rearmost position |
| Headrest Height | Lowest position |
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Occupant Detection / Utility / Zero Point Calibration & Sensitivity Check.
Perform zero point calibration and sensitivity check by following the prompts on the Techstream screen.