CAMSHAFT OIL CONTROL VALVE > INSPECTION |
| 1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 1 - 2 | 6.9 to 7.9 Ω at 20°C (68°F) |
![]() |
Check the operation.
| *1 | Spool Valve |
| *2 | Battery |
Connect a battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the spool valve.
| Condition | Specified Condition |
| Battery voltage is applied | Valve moves in black arrow direction shown in illustration |
| Battery voltage is not applied | Valve moves in white arrow direction shown in illustration |