Home › General › SPECIFICATIONS › 2GR-FE ENGINE CONTROL

2GR-FE ENGINE CONTROL > SERVICE DATA



Spark plug

Spark plug type
DENSO made
FK20HR11
Standard electrode gap
for new spark plug
1.0 to 1.1 mm (0.0394 to 0.0433 in.)
Maximum electrode gap
for used spark plug
1.4 mm (0.0551 in.)
Camshaft timing oil control valve assembly

Resistance
at 20°C (68°F)
6.9 to 7.9 Ω
Throttle body

Resistance
2 (M+) - 1 (M-)
0.3 to 100 Ω at 20°C (68°F)
Vacuum switching valve (for Engine Mounting)

Resistance
at 20°C (68°F)
19 to 21 Ω
Acceleration pedal sensor

Standard voltage (Accelerator Position No.1)
Released
0.5 to 1.1 V
Depressed
2.6 to 4.5 V
Standard voltage (Accelerator Position No.2)
Released
1.2 to 2.0 V
Depressed
3.4 to 4.8 V
Mass air flow meter

Resistance
1 (THA) - 2 (E2)
13.6 to 18.4 kΩ at -20°C (-4°F)
1 (THA) - 2 (E2)
2.21 to 2.69 kΩ at 20°C (68°F)
1 (THA) - 2 (E2)
0.49 to 0.67 kΩ at 60°C (140°F)
Crankshaft position sensor

Resistance
Cold
1630 to 2740 Ω
Hot
2065 to 3225 Ω
Engine coolant temperature sensor

Resistance
20°C (68°F)
2.32 to 2.59 kΩ
80°C (176°F)
0.310 to 0.326 kΩ
Knock sensor

Resistance
at 20°C (68°F)
120 to 280 kΩ
Air fuel ratio sensor

Resistance
1 (HA1A) - 2 (+B)
1.6 to 3.2 Ω at 20°C (68°F)
1 (HA1A) - 4 (A1A-)
10 kΩ or higher
Oxygen sensor

Resistance
(for Bank 1 Sensor 2)
2 (HT1B) - 1 (+B)
11 to 16 Ω at 20°C (68°F)
2 (HT1B) - 3 (E2)
10 kΩ or higher
Resistance
(for Bank 2 Sensor 2)
1 (HT2B) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
1 (HT2B) - 4 (E2)
10 kΩ or higher
EFI MAIN relay

Specified Condition
No. 1 integration relay B-1 - No. 1 integration relay A-8
Battery voltage is not applied between terminals C-7 and E-2
10 kΩ or higher
No. 1 integration relay B-1 - No. 1 integration relay A-8
Battery voltage is applied between terminals C-7 and E-2
Below 1 Ω
No. 1 integration relay B-1 - No. 1 integration relay C-3
No. 1 integration relay B-1 - No. 1 integration relay C-4
No. 1 integration relay B-1 - No. 1 integration relay C-6
No. 1 integration relay B-1 - No. 1 integration relay C-9
No. 1 integration relay B-1 - No. 1 integration relay C-10
A/F HTR relay

Specified Condition
No. 1 integration relay A-6 - No. 1 integration relay D-1
Battery voltage is not applied between terminals A-8 and E-2
10 kΩ or higher
No. 1 integration relay A-6 - No. 1 integration relay D-1
Battery voltage is applied between terminals A-8 and E-2
Below 1 Ω
No. 1 integration relay A-7 - No. 1 integration relay D-1
IG2 relay

Specified Condition
No. 1 integration relay A-1 - No. 1 integration relay D-3
Battery voltage is not applied between terminals C-8 and E-2
10 kΩ or higher
No. 1 integration relay A-1 - No. 1 integration relay D-3
Battery voltage is applied between terminals C-8 and E-2
Below 1 Ω
No. 1 integration relay A-3 - No. 1 integration relay D-3
No. 1 integration relay A-5 - No. 1 integration relay D-3
No. 1 integration relay C-1 - No. 1 integration relay D-3
No. 1 integration relay C-2 - No. 1 integration relay D-3
No. 1 integration relay C-5 - No. 1 integration relay D-3