AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > CHECK MODE PROCEDURE

for Preparation Click here



REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
E227433
  1. Start the engine.

  2. Check that A/C switch indicator remains on when the following conditions are met.
    Measurement Condition 
    Item
    Condition
    A/C Switch
    On
    A/C operation time
    15 minutes or more
    Ambient temperature*
    0 to 49°C (32 to 120°F)
    Engine coolant temperature
    45°C (113°F) or more
    *: If the ambient temperature is not within the range shown, do not perform this check.

    HINT:
    The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.

  3. Connect the Techstream to the DLC3.

  4. Check for DTC B14B8.

    Result 
    Result
    Amount of Refrigerant
    Corrective Action
    DTC B14B8 is output
    Empty or nearly empty
    Check for refrigerant leaks using a halogen leak detector, and repair if necessary (Click here).
    DTC B14B8 is not output
    Correct or insufficient
    Perform a refrigerant shortage check using the Techstream.


REFRIGERANT SHORTAGE CHECK USING THE TECHSTREAM
  1. Connect the Techstream to the DLC3.

  2. Start the engine.

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Shortage Check.

  5. According to the display on the Techstream, perform the refrigerant shortage check when the following conditions are met.
    Measurement Condition 
    Item
    Condition
    A/C Switch
    On
    Ambient temperature*
    0 to 49°C (32 to 120°F)
    R/F Switch
    Fresh (Ambient temperature is 31°C (87°F) or more)
    Recirculation (Ambient temperature is 30°C (86°F) or less)
    Blower Speed
    HI
    Temperature Setting
    MAX HOT
    *: If the ambient temperature is not within the range shown, do not perform this check.

    HINT:
    1. Refer to the Techstream operator's manual for further details.
    2. A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
    3. DTCs are not stored when performing the refrigerant shortage check using the Techstream.


    Result 
    Result
    Amount of Refrigerant
    Corrective Action
    Refrigerant shortage
    Insufficient or leakage
    1. Check for refrigerant leaks using a halogen leak detector, and repair if necessary (Click here).
    2. Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
    Refrigerant correct
    Correct
    -