Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

  5. Check the value(s) by referring to the table below.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Ambient temperature sensor (Thermistor assembly) /
    Min.: -23.30°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    -
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    Min.: -30.80°C (-23.44°F)
    Max.: 50.80°C (123.44°F)
    -
    -
    Evaporator Fin Thermistor
    Evaporator temperature sensor (No. 1 cooler thermistor) /
    Min.: -29.70°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    -
    Evaporator Target Temp
    Evaporator target temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Evaporator target temperature displayed
    -
    Engine Coolant Temp
    Engine coolant temperature sensor /
    Min.: 1.30°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature displayed
    -
    Blower Motor Speed Level
    Blower motor speed level /
    Min.: 0
    Max.: 31
    Displayed speed level increases in range between 0 and 31 as blower motor speed increases
    -
    Regulator Pressure Sensor
    Air conditioning pressure sensor /
    Min.: -0.4566 MPaG
    Max.: 3.2943 MPaG
    Actual pressure is displayed
    -
    Regulator Control Current
    Solenoid valve control current /
    Min.: 0 A
    Max.: 0.997 A
    Value changes between 0 A and 0.997 A in accordance with solenoid valve operation
    -
    Air Mix Servo Targ Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse /
    Min.: 0
    Max.: 255
    MAX. COLD: 105 (pulse)
    MAX. HOT: 7 (pulse)
    -
    Air Mix Servo Actual Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse /
    Min.: 0
    Max.: 255
    MAX. COLD: 105 (pulse)
    MAX. HOT: 7 (pulse)
    -
    Air Outlet Servo Pulse (D)
    No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse /
    Min.: 0
    Max.: 255
    FACE: 8 (pulse)
    B/L: 30 (pulse)
    FOOT (except MAX. HOT): 67 (pulse)
    FOOT (MAX. HOT): 74 (pulse)
    FOOT/DEF: 80 (pulse)
    DEF: 97 (pulse)
    -
    Air Outlet Servo Actu Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse /
    Min.: 0
    Max.: 255
    FACE: 8 (pulse)
    B/L: 30 (pulse)
    FOOT (except MAX. HOT): 67 (pulse)
    FOOT (MAX. HOT): 74 (pulse)
    FOOT/DEF: 80 (pulse)
    DEF: 97 (pulse)
    -
    Air Inlet Damper Targ Pulse
    No. 1 blower damper servo sub-assembly (air inlet) target pulse /
    Min.: 0
    Max.: 255
    RECIRCULATION: 7 (pulse)
    FRESH: 28 (pulse)
    -
    Air Inlet Damper Actual Pulse
    No. 1 blower damper servo sub-assembly (air inlet) actual pulse /
    Min.: 0
    Max.: 255
    RECIRCULATION: 7 (pulse)
    FRESH: 28 (pulse)
    -
    Evaporator Control
    Evaporator Control /
    Auto or Manual
    Customized value displayed
    -
    Refrigerant Shortage Check
    Refrigerant shortage check /
    ON, OFF
    Customized value displayed
    -
    Pls Servo Test Sts
    Pulse servo motor test status/
    Wait, Move, Comp, Error, Stop
    Pulse servo motor test status
    -
    Flow Sensor
    Flow sensor /
    Min.: 0.0 V
    Max.: 5.0 V
    A/C on, Blower switch HI: 0.7 to 3.8 V
    A/C off, Blower switch off: 3.8 to 4.2 V
    Flow sensor is malfunctioning when a constant value between 0.7 and 4.2 V is displayed continuously for more than 4 seconds.
    A/C Cutoff Signal
    A/C control cutoff signal /
    OFF or ON
    A/C switch on: OFF
    A/C switch off: ON
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0
    Max.: 255
    Number of DTCs displayed
    -


ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch to ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

  5. Check the operation by referring to the table below.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower with fan motor sub-assembly
    Min.: 0, Max.: 31
    -
    Magnetic Clutch Relay
    A/C system operation
    OFF, ON
    -
    Defogger Relay (Rear)
    Defogger relay (engine room junction block assembly)
    OFF, ON
    -
    Air Mix Servo Targ Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse
    Min.: 0, Max.: 255
    Operates between 7 and 105 pulses
    Air Outlet Servo Pulse (D)
    No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse
    Min.: 0, Max.: 255
    Operates between 8 and 97 pulses
    Air Inlet Damper Targ Pulse
    No. 1 blower damper servo sub-assembly (air inlet) pulse
    Min.: 0, Max.: 255
    Operates between 7 and 28 pulses