DTC P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
DTC P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2769 | TCM detects a short in the shift solenoid valve SL circuit when the shift solenoid valve SL is operated (2 trip detection logic). |
|
| P2770 | TCM detects an open in the shift solenoid valve SL circuit when the shift solenoid valve SL is not operated (2 trip detection logic). |
|
| Related DTCs | P2769: Shift solenoid valve SL/Range check (Low resistance) P2770: Shift solenoid valve SL/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve SL |
| Frequency of operation | Continuous |
| Duration | 1 time |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Solenoid | ON |
| Time after solenoid OFF to ON | More than 0.008 sec. |
| The monitor will run whenever the following DTCs are not present | None |
| Solenoid | ON |
| Time after solenoid ON to OFF | More than 0.008 sec. |
| Intelligent power MOS diagnosis fail signals detected while the solenoid is operated | Fail at solenoid resistance: 8 Ω or less |
| Intelligent power MOS diagnosis fail signals detected while the solenoid is not operated | Fail at solenoid resistance: 100 kΩ or more |
| Shift solenoid valve SL | Resistance: 11 to 15 Ω at 20°C (68°F) |

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL) |
![]() |
Remove the TCM from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (SL) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | ||
| ||
| 2.INSPECT SHIFT SOLENOID VALVE SL |
![]() |
Remove shift solenoid valve SL.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (SL) - Solenoid Body (SL) | 20°C (68°F) | 11 to 15 Ω |
| *1 | Shift Solenoid Valve SL |
|
| ||||
| OK | ||
| ||