Home › Engine / Hybrid System ยท 2AR-FE › EMISSION CONTROL › PCV VALVE

PCV VALVE > INSTALLATION

for Preparation Click here



1. INSTALL VENTILATION VALVE SUB-ASSEMBLY
  1. Apply adhesive to 2 or 3 threads of the ventilation valve sub-assembly.

    Adhesive:
    Toyota genuine adhesive 1324, three bond 1324 or equivalent

  1. Using a 19 mm deep socket wrench, install the ventilation valve sub-assembly.

    Torque:
    27 N*m{ 275 kgf*cm , 20 ft.*lbf }

  1. Connect the No. 2 ventilation hose to the ventilation valve sub-assembly.



2. INSTALL INTAKE MANIFOLD
(Click here)