Home › Vehicle Interior › LIGHTING (INT) › RELAY

RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT LIGHT CUT RELAY


    E222294E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Light Cut Relay)
    If the result is not as specified, replace the light cut relay.