POWER STEERING SYSTEM (for 2GR-FE) > DATA LIST / ACTIVE TEST |
| DATA LIST |
Turn the engine switch off.
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Enter the following menus: Chassis / EMPS / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Meter Vehicle Velocity | Vehicle speed from meter/ Min.: 0 km/h (0 mph) Max.: 300.0 km/h (186.4 mph) | 0 km/h (0 mph) | Engine running and vehicle stopped |
| No significant fluctuation | Engine running and vehicle driven at a constant speed | ||
| Engine Revolution | Engine speed/ Min.: 0 rpm Max.: 12800 rpm | No significant fluctuation | Engine running at a constant speed |
| Motor Actual Current | Amount of current to motor/ Min.: -327.68 A Max.: 327.67 A | The value rises | Engine running and steering wheel being turned |
| Command Value Current | Demanded amount of current to motor/ Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort - The value rises when turning left - The value descends when turning right | Engine running and steering wheel being turned |
| Steering Angle Velocity | Steering angle speed/ Min.: -32768 deg/s Max.: 32767 deg/s | Value changes in proportion to steering speed - The value rises when turning left - The value descends when turning right | Engine running and steering wheel being turned |
| Thermistor Temperature | ECU substrate temperature/ Min.: -40°C (-40°F) Max.: 150°C (302°F) | -40°C to 150°C (-40°F to 302°F) | Engine running |
| PIG Power Supply | Power source voltage to active motor/ Min.: 0 V Max.: 20.1531 V | 9 to 16 V | Engine running and steering wheel being turned |
| IG Power Supply | IG power source voltage/ Min.: 0 V Max.: 20.1531 V | 9 to 16 V | Engine switch on (IG) |
| Steering Wheel Torque | Steering wheel torque/ Min.: -327.68 Nm Max.: 7.00 Nm | Value changes in proportion to steering effort - The value rises when turning left - The value descends when turning right | Engine running and steering wheel being turned |
| Motor Rotation Angle | Motor rotation angle/ Min.: 0 deg Max.: 1441.770 deg | During steering operation, motor rotation angle value changes from 0 to 360° | Engine running and steering wheel being turned |
| Motor Voltage | Motor power supply voltage/ Min.: 0 V Max.: 98.000 V | 9 to 16 V | Engine running |
| Motor Terminal Volt (U) | Motor terminal voltage (A phase)/ Min.: 0 V Max.: 98.000 V | Value changes within 4 to 35 V range | Engine running and steering wheel being turned |
| Motor Terminal Volt (V) | Motor terminal voltage (B phase)/ Min.: 0 V Max.: 98.000 V | Value changes within 4 to 35 V range | Engine running and steering wheel being turned |
| Motor Terminal Volt (W) | Motor terminal voltage (C phase)/ Min.: 0 V Max.: 98.000 V | Value changes within 4 to 35 V range | Engine running and steering wheel being turned |
| Torque Sensor 1 Output | Torque sensor voltage/ Min.: 0 V Max.: 4.9725 V | 2.3 to 2.7 V | Engine running and steering wheel not being turned (without load) |
| 2.5 to 4.7 V | Engine running and steering wheel being turned to the right with vehicle stopped | ||
| 0.3 to 2.5 V | Engine running and steering wheel being turned to the left with vehicle stopped | ||
| Torque Sensor 2 Output | Torque sensor voltage/ Min.: 0 V Max.: 4.9725 V | 2.3 to 2.7 V | Engine running and steering wheel not being turned (without load) |
| 0.3 to 2.5 V | Engine running and steering wheel being turned to the right with vehicle stopped | ||
| 2.5 to 4.7 V | Engine running and steering wheel being turned to the left with vehicle stopped | ||
| IG ON/OFF Times | Number of times of engine switch ON/OFF after fail detection/ Min.: 0 times Max.: 65535 times | - | This value indicates the number of times of engine switch ON/OFF after the latest DTC detection. |
| Motor Overheat Record | Continuous overheat prevention control record/ Unrec or Rec | Unrec | Unrec: Unrecorded Rec: Recorded |
| Motor Lo Power Record | PIG power source voltage drop record/ Unrec or Rec | Unrec | Unrec: Unrecorded Rec: Recorded |
| Eng Rev Inter Record | Record of engine speed signal interruption/ Unrec or Rec | Unrec | Unrec: Unrecorded Rec: Recorded |
| Spd Sig Invalid Record | Record of vehicle speed signal invalid/ Unrec or Rec | Unrec | Unrec: Unrecorded Rec: Recorded |
| Battery Voltage Lo Record | Battery voltage reduction history/ Min.: 0 times, Max.: 65535 times | 0 to 65535 | - |
| Battery Voltage | Battery voltage/ Min.: 0 V Max.: 25.5 V | 9 to 16 V | Engine switch on (IG) |
| PS Assist Signal | Power steering assist signal/ ON or OFF | OFF | Engine switch on (IG) |
| ON | Engine running | ||
| The Number of DTCs | Number of detected DTCs when freeze frame data stored/ Min.: 0 Max.: 255 | 0 to 255 | - |