Home › Engine / Hybrid System ยท 2GR-FE › ENGINE CONTROL › SFI SYSTEM

DTC    P2420    Evaporative Emission System Switching Valve Control Circuit High

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P2420
Vent valve stuck open (vent)
Following condition met during key-off EVAP monitor:
  1. EVAP pressure change when vent valve closed (on) less than 0.3 kPa(gauge) [2.25 mmHg(gauge)]
  1. Canister pump module (reference orifice, leak detection pump, vent valve)
  2. Connector/wire harness (Canister pump module - ECM)
  3. Canister (filter inside canister clogged)
  4. ECM
While engine switch off
2 trip

HINT:
The vent valve is built into the canister pump module.


DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System .

MONITOR DESCRIPTION

5 hours* after the engine switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the engine switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the engine switch is turned off, the monitor check starts 2.5 hours later.


Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after engine switch is turned off.
-
A
Atmospheric pressure measurement
Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B
First reference pressure measurement
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
360 seconds
C
EVAP system pressure measurement
Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and then EVAP system pressure is measured. Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E
Second reference pressure measurement
After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that there is a leak in EVAP system.
60 seconds
-
Final check
Atmospheric pressure is measured and then monitoring result is recorded by ECM.
-
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E37


Text in Illustration 
*1
Purge VSV: Off (Closed)
*2
Purge VSV: On (Open)
*3
Vent Valve: Off (Vent)
*4
Vent Valve: On (Closed)
*5
Leak Detection Pump: Off
*6
Leak Detection Pump: On
*7
Reference Orifice (0.02 inch)
*8
Canister Pressure Sensor
*9
Canister
*10
Fuel Tank
*11
Canister Pump Module
*12
Canister Filter
*a
Operation A:
Atmospheric Pressure Measurement
*b
Operation B, E:
Reference Pressure Measurement
*c
Operation C:
EVAP System Pressure Measurement
*d
Operation D:
Purge VSV Monitor
*e
Atmospheric Pressure
*f
Negative Pressure
P2420: Vent valve stuck open (vent)
In operation C, the vent valve turns on (closed) and the EVAP system pressure is then measured by the ECM using the canister pressure sensor to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and stores the DTC.

A106067E68


MONITOR STRATEGY


Required Sensors/Components (Main)
Purge VSV
Canister pump module
Required Sensors/Components (Related)
-
Frequency of Operation
Once per driving cycle
Duration
Within 3 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever the following DTCs are not stored
None
Atmospheric pressure
70 kPa(abs) [525 mmHg(abs)] or higher, and less than 110 kPa(abs) [825 mmHg(abs)]
Battery voltage
10.5 V or higher
Vehicle speed
Less than 4 km/h (2.5 mph)
Engine switch
Off
Time after key-off
5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of the following conditions met before key-off
Conditions 1 and 2
1. Duration that vehicle is driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4°C (40°F) or higher, and less than 35°C (95°F)
Intake air temperature
4.4°C (40°F) or higher, and less than 35°C (95°F)

TYPICAL MALFUNCTION THRESHOLDS


EVAP pressure change after EVAP canister vent valve on
Less than 0.3 kPa(gauge) [2.25 mmHg(gauge)]

MONITOR RESULT

Refer to EVAP System .

CONFIRMATION DRIVING PATTERN

NOTICE:
  1. The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 24 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
  3. Do not run the engine during this operation.
  4. When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).

  1. Connect the Techstream to the DLC3.
  2. Turn the engine switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the engine switch off and wait for at least 30 seconds.
  5. Turn the engine switch on (IG) and turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.
  7. After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine / Utility / All Readiness.
  8. Input the DTC: P2420.
  9. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.

  10. If the judgment result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


INSPECTION PROCEDURE

Refer to EVAP System .