DTC P060A Internal Control Module Monitoring Processor Performance |
| DTC No. | DTC Detection Condition | Trouble Area |
| P060A | A CPU reset is performed after one of the following conditions is met (1 trip detection logic):
| ECM |
| Related DTCs | P060A: Internal control module monitoring processor performance |
| Required Sensors/Components (Main) | ECM |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | - |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not stored | None |
| Either of the following conditions is met | 1 or 2 |
| 1. All of the following conditions are met | - |
| CPU reset | 1 time or more |
| Learned throttle position - Learned accelerator pedal position | 0.4 V or higher |
| Electronic throttle actuator | Off |
| 2. CPU reset | 2 times or more |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.READ OUTPUT DTC (DTC P060A) |
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Clear the DTCs (Click here).
Turn the Techstream off.
Turn the engine switch off.
Disconnect the Techstream.
Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
Connect the cable to the negative (-) battery terminal.
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Wait for 16 seconds or more.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P060A is output | B |
|
| ||||
| A | ||
| ||