Home › Engine / Hybrid System · 2GR-FE › ENGINE CONTROL › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    A256126E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    -
    10 kΩ or higher
    Text in Illustration 
    *a
    Component without harness connected
    (Heated Oxygen Sensor)

    If the resistance is not as specified, replace the heated oxygen sensor.



2. INSPECT HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


    A192463E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E2)
    -
    10 kΩ or higher
    Text in Illustration 
    *a
    Component without harness connected
    (Heated Oxygen Sensor)

    If the resistance is not as specified, replace the heated oxygen sensor.