CONSTRUCTION
The ATF pressure switches are located in the output fluid passages of shift solenoid valves SL1, SL2 and SLU, and they turn on and off in accordance with the output fluid pressure of shift solenoid valves SL1, SL2 and SLU.
The TCM detects malfunctions in shift solenoid valves SLU and SL used in lock-up control in accordance with the on/off signals from ATF pressure switch 3 located in the SLU output fluid passage.
When any of SL1 to SL4 shift solenoid valves malfunction, the TCM determines the appropriate fail-safe operation in accordance with the on/off signals from ATF pressure switches 1 and 2 located in the SL1 and SL2 output fluid passages.
| *1 | ATF Pressure Switch | *2 | Lower Valve Body |