CONSTRUCTION
The compressor with pulley assembly is a continuously variable capacity type air conditioning compressor. Its capacity can be varied in accordance with the cooling load of the air conditioning system.
The compressor with pulley assembly consists of a pulley, shaft, lug plate, swash plate, piston, shoe, crank chamber, cylinder, solenoid valve with built-in Crank chamber to Suction passage (CS) valve, air conditioning mass flow sensor, oil separator and variable suction side throttle.
The oil separator consists of an oil separator chamber and an oil separator cylinder.
| *1 | Magnetic Clutch Assembly | *2 | Air Conditioning Lock Sensor |
| *3 | Lug Plate | *4 | Crank Chamber |
| *5 | Shoe | *6 | Swash Plate |
| *7 | Piston | *8 | Cylinder |
| *9 | Solenoid Valve with Built-in CS Valve | *10 | Shaft |
| *11 | Air Conditioning Mass Flow Sensor | *12 | Oil Separator |
| *13 | Oil Separator Chamber | *14 | Oil Separator Cylinder |
| *15 | Variable Suction Side Throttle | - | - |
If the compressor locks, the steel with magnetic clutch pulley turns the magnetic clutch off to protect the drive belt and separates the pulley from the cooler compressor assembly.
| *1 | Pulley Portion | *2 | Magnetic Clutch |
| *3 | Shaft | - | - |
OPERATION
Variable Capacity Operation
A solenoid valve is connected to the suction passage, the discharge passage and the crank chamber passage.
The solenoid valve operates under duty cycle control in accordance with the signals from the air conditioning amplifier assembly.
When the solenoid valve opens (solenoid coil is not energized), the difference in pressure disappears. Then, the pressure that is applied to the left side of the piston becomes the same as the pressure that is applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lug plate. As a result, the piston stroke and discharge capacity increases.
When the solenoid valve opens (solenoid coil is not energized), the difference in pressure disappears. Then, the pressure that is applied to the left side of the piston becomes the same as the pressure that is applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lug plate. As a result, the piston stroke becomes small, decreasing the discharge capacity.
Air Conditioning Lock Sensor Operation
The air conditioning lock sensor outputs a pulley rotation signal to the air conditioning amplifier assembly.
The air conditioning amplifier assembly compares this signal with the engine speed signal sent from the ECM to judge if the compressor is locked. If the compressor is locked, the magnetic clutch is turned off.
Air Conditioning Mass Flow Sensor Operation
Using a spool that changes its position according to the amount of refrigerant flow, the air conditioning mass flow sensor detects the amount of refrigerant flow.
The air conditioning mass flow sensor outputs a voltage by converting the change of magnetic flux that occurs due to the magnet that is installed on the spool.
The spool changes its position according to the pressure difference between the pressure before and after the refrigerant flow throttle.
If the amount of refrigerant flow is small, the pressure difference between pressure difference inlet chamber A and B is low, allowing the force of spring B to push up the spool.
If the amount of refrigerant flow is large, the pressure difference between pressure difference inlet chamber A and B is high. The pressure difference overwhelms the force of spring B, and the spool moves down.
Based on the amount of refrigerant flow detected by the air conditioning mass flow sensor, the air conditioning amplifier assembly and ECM cooperatively control the cooler compressor assembly and the engine.
Oil Separator Operation
A mixture of refrigerant and cooler compressor oil flows into the oil separator chamber from the discharge chamber (*a).
The force of the refrigerant and oil mixture flow turns the oil separator cylinder, allowing the oil and refrigerant to be centrifugally separated (*b).
The separated refrigerant flows to the cooler condenser assembly through the discharge port (*c).
The separated oil circulates and lubricates the inside of the cooler compressor assembly by flowing through the oil reservoir chamber, inlet chamber, cylinder and discharge chamber. In addition, the amount of oil that is discharged by the cooler compressor assembly is suppressed (*d).
The oil separator is installed in the refrigerant passage to separate cooler compressor oil from the refrigerant that is discharged. This helps to prevent the cooler compressor oil from flowing into the air conditioning system and reducing cooling effectiveness (*e).
Variable Suction Side Throttle Operation
Refrigerant inlet pressure is applied to the top of the variable suction side throttle and crank chamber pressure to the bottom of the variable suction side throttle.
The pressure difference moves the variable suction side throttle up and down, expanding and contracting the refrigerant inlet passage.
When the refrigerant flow is at a maximum, the refrigerant inlet pressure is greater than the crank chamber pressure. This causes the variable suction side throttle to move down, fully opening the refrigerant inlet passage and lowering the refrigerant inlet resistance.
When the amount of refrigerant flow is controlled, the crank chamber pressure is greater than the refrigerant inlet pressure, raising the variable inlet throttle to contract the flow passage.
These controls suppress noise by reducing pulsation from the refrigerant inlet.
CS Valve Operation
The Crank chamber to Suction passage (CS) valve, built into the solenoid valve, operates in accordance with the suction pressure. The CS valve consists of passage A and passage B.
If the vehicle is left parked for a long period, refrigerant may accumulate in the crank chamber due to the heat capacity difference.
The solenoid valve is controlled by the air conditioning amplifier assembly. While the compressor with pulley assembly is operating, the solenoid valve pushes down the CS valve rod and open passage A (*a).
Under the above condition, only if the refrigerant accumulates in the crank chamber, the crank chamber pressure will become high. As a result, the bellows will contract because of the pressure difference with its internal pressure (vacuum), and opens passage B (*b).