OUTLINE
The Controller Area Network (CAN) uses 2 different types of CAN buses:
The CAN V bus and CAN sub bus 2 are HS-CAN buses that operate at 500 kbps.
The CAN sub bus 1 is an MS-CAN bus that operates at 250 kbps.
Each CAN bus has 2 terminating resistors which are necessary for accurate judgment of communication.
The terminating resistors for each bus are located as shown in the following table.
| Speed Communication | Bus | Terminating Resistor Location |
|---|---|---|
| High-speed (HS-CAN) | CAN V Bus | ·
ECM ·
Combination Meter Assembly |
| CAN Sub Bus 2 | ·
Network Gateway ECU ·
CAN Junction Connector |
|
| Middle-speed (MS-CAN) | CAN Sub Bus 1 | ·
Main Body ECU (Multiplex Network Body ECU) ·
CAN Junction Connector |
The network gateway ECU has a gateway function and is used to transmit data between the CAN V bus and the CAN sub bus 2.
The main body ECU (multiplex network body ECU) has a gateway function and is used to transmit data between the CAN V bus and the CAN sub bus 1.