Home › General › SPECIFICATIONS › 2GR-FE COOLING
RM2030EQ _V1 General _014632 SPECIFICATIONS _0074346 2GR-FE COOLING F

SPECIFICATIONS  2GR-FE COOLING  SERVICE DATA  


THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 7.7 mm (0.3031 in.) or more at 95°C (203°F)

COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 10.6 to 16.6 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 10.6 to 16.6 A

COOLING FAN RELAY
Item Tester Connection Specified Condition
Fan relay 3 - 5 10 kΩor higher
(Battery voltage is not applied between terminals 1 and 2)
3 - 5 Below 1 Ω
(Battery voltage is applied between terminals 1 and 2)

RADIATOR
Item Condition Specified Condition
Radiator cap Standard value
(for brand-new cap)
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum standard value
(for used cap)
78.5 kPa (0.8 kgf/cm2, 11.4 psi)

COOLANT
Capacity Classification
9.4 liters (9.9 US qts, 8.3 Imp. qts) Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).