11401G
1.INSPECT CRANK POSITION SENSOR
Measure the resistance according to the value(s) in the table below.
| Temperature | Specified Condition |
|---|---|
| Cold | 1630 to 2740 Ω |
| Hot | 2065 to 3225 Ω |
"Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122 °F) and "Hot" is from 50 to 100°C (122 to 212°F).
If the resistance is not as specified, replace the crank position sensor.